2. Cleaning door, top
3. Combustion chamber
4. Burner
5. Cleaning door, bottom
6. Observation flap
7. Air apertures for the combustion
8. Blow-off faucet (on type 2.5 this is placed between the fire box and the
hopper)
8a. Delivery screw for air chamber (on type 2.5 this is placed directly over
the bottom frame on the right-hand side.
9. Ignition / striking arc
10. Cleaning opening (for hopper)
11. Fuel worm conveyor/auger (transports the fuel inwards)
12. Back-burn safety valve
13. Blower (provides air for the combustion)
14. Stirrer/agitator (only for the version firing with wood chips)
15. Air intake (there is one of these on both sides)
16. Cleaning flap (there is one of these on both sides)
17. Covers for hopper (reversible)