3.9. SET PARAMETER
Press key 3 seconds. The screen will shows the menu. Now show menu. Press SET/0~9 sequentially it displays:
rAngE (set limit)
UnIt5 (choose unit)
A-OFF (choose auto power off)
FILt (display filter)
2ero (set auto T )
bU22Er (set buzzer)
d (choose division)
d-dP (choose single or dual display)
3.9.1 Set range of auto-zero:
When it shows “rAngE”, press and then SET to choose “on” or “oFF”, “on” is start the function, “oFF” is exit, press to
confirm.
When choose “on” and press , now you will weigh with limit; led “-”(under limit) lighting, first digit is blinking, press once to
increase the current digit, press to confirm and edit next digit; once you finish to set all “-“ digits, when you press , led “+”
turns on, then you can config upper limit with the same procedure; when finishing auto exit and set “over” after setting into weighing.
When low limit > high limit, it displays “oFF”, then exit.
Caution: when the display is not stable, no led lights.
Alarming indicate: if bu22er parameter is set to on, alarm will sound if the weigh over the pan is on ok zone.
3.9.2 Change Unit
When shows “UnIt5”, press , then press SET/0~9 to choose, then press to confirm and exit.
Units: x9 (kg), pc5 (counting),lb.lb (lb), Lb.o2 (lb.oz), 9 (g).
Counting: when the screen shows “pc5” press T . Now the led ir turned on. Press longer ON/0 , shows count and returns
to 0. Then place the sample and press . Pres and to introduce the number of pieces that compose the sample.
After to finish the sample “pc5” and the led “ ” is turned on.
To exit from the counting function, select the unit.
Caution: Enter quantities of up to 30000.
3.9.3 A-oFF (Choose to turn off automatically)
When menu displays A-oFF, press to enter, press to choose “n” o “y”, “n” is not auto power off, “y” means, after 10
minutes in zero, auto-off.
3.9.4 Change display filter:
When it displays “FILtX” (FILt1 means one step change display, FILt2 means 3-4 steps change display, FILt3 means 6-8 steps chan-
ge display) Press to change, press to confirm and exit.
3.9.5 Set range of auto-zero:
When it displays 2ero, press , now shows 2ero x.x (x.x is the range: 0.5d, 1d, 1.5d, 2d, 2.5d, 3d, 3.5d, 4d, 4.5d, 5d. “d” is the
division value when n=3000). Press to choose and to confirm.
3.9.6 bUZZEr (set buzze)
When menu displays bU22Er, press to enter, press to choose “on” or “oFF”, press to confirm.
3.9.7 Change division value
When menu displays d, press to enter, press to choose division.