Questions and Answers:

Bayer HealthCare Ascensia Breeze Specifications

General IconGeneral
Product TypeBlood Glucose Meter
BrandBayer HealthCare
ModelAscensia Breeze
Test Strip TypeAscensia Breeze Test Strips
Test Time5 seconds
Power SourceBattery
BatteryCR2032
Dimensions3.3 x 2.2 x 0.9 inches (84 x 56 x 23 mm)
Weight1.5 oz (43 g) with battery
Operating Temperature50-104°F (10-40°C)
Sample Size1.0 μL
DisplayLCD
Measuring Range20-600 mg/dL
Operating Humidity10 to 90% RH

Summary

Ascensia BREEZE Meter Overview

Meter Button Functions

Explains the operation of each button: On/Off, Memory, Set-Up, Up/Down, and OK.

Everyday Use

Inserting a 10-Test Disc

Step-by-step guide for loading the 10-test disc into the meter.

Running a Blood Glucose Test

Applying the Blood Sample

How to obtain a blood sample and apply it correctly to the test strip.

Multiple Site Testing

Running a Control Test

Control Test Procedure

Step-by-step instructions for performing a quality control test to verify system accuracy.

Setting Time, Date, and Features

Transfer Test Results to a Computer

Cleaning Your Meter

Meter Cleaning Procedure

Instructions for cleaning the meter with a moist, lint-free tissue.

Biohazard Safety Precautions

Important safety guidelines for handling potentially infectious materials.

Replacing the Battery

Battery Replacement Warnings

Important safety notes regarding battery handling and disposal.

Battery Replacement Procedure

Detailed steps for removing the old battery and inserting a new one.

Performance Evaluations

Bayer Accuracy Evaluation

Describes how meter accuracy was tested against a reference analyzer.

Multiple Site Testing Evaluation

Solving Problems

Common Issue Resolution

Troubleshooting guide to resolve common issues with the meter.

Troubleshooting and Error Codes

Error Codes and Meanings

Explains common error codes and their meanings with recommended actions.

Meter Status Indicators

Explains indicators for low battery, malfunction, and open status.

Meter Error Codes E7-E10

Explains specific error codes related to meter function and blood glucose levels.

Meter Error Codes E11+ and Operational Errors

Covers meter malfunctions and operational issues like blank display or failure to start.

Control Test and Display Issues

Addresses control test results out of range and display segment problems.

Customer Service