2.3 Control Panel Operation
1. Beam Position: Rotates the beam clockwise or anti-clockwise when
the laser head is set to a stationary dot or is in scan mode.
2. Auto/Manual: Toggles the laser between auto leveling mode and
manual mode (for set-up of manual slopes).
3. Power (ON/OFF): Switches the unit on or off.
4. Manual Grade: Drives a manual grade into the laser head when the
unit is in manual mode. (see 3.7)
5. Beam Scan: Puts the beam into scan mode and is used to cycle
through the preset scan angles (0°, 10°, 45°, 90°, 180°, 0°).
6. Rotation Speed: Puts the beam into rotation mode and is used to
cycle through the preset rotation speeds (0, 60, 120, 300, 600, 0 rpm).
(Note: When using a receiver use 600rpm)
7. Anti-Drift: Activates the anti-drift system (see 3.6).
— 7 —