EasyManua.ls Logo

Becker Centronic SunWindSet SWS42 User Manual

Becker Centronic SunWindSet SWS42
100 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
fr
en
de
nl
Centronic
SunWindControl SWC52
Montage- und Betriebsanleitung
Sonnen-Wind-Steuergerät ohne Sensor
Wichtige Informationen für:
den Monteur / die Elektrofachkraft / den Benutzer
Bitte entsprechend weiterleiten!
Diese Anleitung ist vom Benutzer aufzubewahren.
Assembly and Operating Instructions
Sun and wind controller without sensor
Important information for:
Fitters / Electricians / Users
Please forward accordingly!
These instructions must be kept for future reference.
Notice de montage et d’utilisation
Automatisme soleil-vent sans capteur
Informations importantes pour:
l’installateur / l’électricien / l’utilisateur
À transmettre à la personne concernée !
Cette notice doit être conservée par l’utilisateur.
Montage- en gebruiksaanwijzing
Zonne-wind-besturing zonder sensor
Belangrijke informatie voor:
de monteur / de elektricien / de gebruiker
Aan de betreffende personen doorgeven!
De gebruiker dient deze gebruiksaanwijzing te bewaren.
Question and Answer IconNeed help?

Do you have a question about the Becker Centronic SunWindSet SWS42 and is the answer not in the manual?

Becker Centronic SunWindSet SWS42 Specifications

General IconGeneral
BrandBecker
ModelCentronic SunWindSet SWS42
CategoryController
LanguageEnglish

Summary

General

Warranty

Safety Information

Intended use

Explanation of displays and buttons

Manual / automatic sliding switch

Controls manual or automatic operation of the sun protection system.

Buttons under the cover

Contains MENU, OK, +, and RESET buttons for device operation.

Display symbols

Icons representing Programme, Time/date, Text line, Digital display, and Days.

Assembly/connection

Connection as a drive controller

Warning

Risk of injury from electric shock during terminal connections.

Connection as a group controller

Attention

Important note regarding bridging L and C terminals for group control.

Sensors

Sensor Types

Lists compatible Sun, Wind, and Sun/Wind sensor models.

Explanations

Manual/Automatic sliding switch

Explains operation modes controlled by the switch.

OK button

Functionality of the OK button for saving values and activating test mode.

+/- buttons

MENU button

RESET button

Settings menu

SUN ▼ / SUN ▲

Adjusts sun threshold value for sunshade function.

DELAY (only when EXPERT MODE is ON)

Sets delay time for sun sensor commands.

END LIMIT

INTERMEDIATE POSITION

WIND CONTROL

TEST mode

SUMMER/WINTER

Function menu

AWNING/VENETIAN BLINDS

Selects the type of sun protection system.

SWITCHING TIME/BLOCKING TIME

Sets programmable switching and blocking times.

EXPERT MODE OFF/ON

Enables advanced settings and delay time modifications.

Initial operation

Factory settings

TIME/DATE

Default current CET and current date.

SETTING

Default sun threshold, delay times, end limit, and summer/winter settings.

FUNCTION

Default functions like awning, drive controller, external switch, alarm signal.

Programming

Operating mode – overview of menu

Diagram showing menu navigation flow.

TIME/DATE (to set the time and date)

Step-by-step guide to setting time and date.

PROGRAM

Setting Switching/Blocking Times

Configure programmable switching and blocking times.

Programming Notes

Important note about programming effectiveness.

SETTING

SUN setting adjustment

Adjusts the sun threshold value for sunshade activation.

DELAY time setting

Sets delay time for sun sensor commands.

SETTING

INTERMEDIATE POSITION

Sets a custom position between end limits.

FABRIC TENSION/TILT

Adjusts fabric tension or blind slat orientation.

WINTER OFF/ON

Disables automatic and manual commands during winter.

SETTING

WIND MONITORING

Adjusts the wind threshold value for automatic retraction.

TIME END POSITION

Sets the position for end of time-based movement.

TIME INTERM POS

Sets the position for intermediate time-based movement.

SETTING

LIGHT INTERM POS

Sets light-based intermediate position.

LIGHT FABRIC TEN/TILT

Sets light-based fabric tension/tilt position.

LIGHT END POSITION

Sets light-based end position.

SETTING

TEST MODE ON/OFF

Activates or deactivates the test mode.

ENGLISH

Selects the desired national language for the device.

SUMMER/WINTER

Controls automatic clock adjustment for daylight saving.

FUNCTION

AWNING/VENETIAN BLIND

Selects the type of sun protection system.

DRIVE CONTROLLER/GROUP CONTROLLER

Selects the control mode for drives.

RUNNING TIME

Sets the required running time for awnings/blinds.

FUNCTION

EXTERNAL SWITCH/ON/OFF

Processes external control signals.

ALARM SIGNAL ON/OFF

Processes alarm signals.

FUNCTION

BLOCKING TIME/SWITCHING TIME

Select between blocking and switching time settings.

EXPERT MODE OFF/ON

Enables or disables expert mode for advanced settings.

INITIAL OPERATION

Records the initial operation date for servicing.

Technical data

Changing the batteries

Note

Pre-set values remain stored after battery change.

Cleaning

What to do if...?

Drive not functioning or moving incorrectly

Addresses drive operation and direction issues.

Control commands not executing

Fixes issues with automatic commands or parameter changes.

End limit position issues

Resolves problems with curtain/canopy reaching end limits.