084-121076
This Beckett FR Series centrifugal pump is magnetically driven and contains no seals to leak or wear
out. It also contains no oil as other types of submersible utility pumps do, thereby eliminating the pos-
sibility of oil leaks which can foul your water. All electrical parts and connections are completely en-
capsulated with epoxy. These features, combined with very low energy consumption, make for a safe
and convenient pump which is economical to operate. In addition, it is essentially maintenance-free.
The Beckett FR Series pump is designed to operate completely submerged. Cleaning of the filter can
be reduced by placing the pump on a brick or patio stone in the water to raise it above the level of the
debris which accumulates on the bottom.
Use:
A prefilter is supplied with the pump. Using and maintaining a clean prefilter will greatly decrease
maintenance in cleaning the impeller assembly as well as providing better water filtration and pump
flow. See Page 2 - Prefilter Cleaning.
Prefilter:
The only serviceable part is the impeller assembly. It can be cleaned and inspected by removing the
four screws holding the volute housing in place and lifting out the housing and impeller assembly.
See Page 3 for diagram. Never attempt to disassemble the impeller assembly. If it becomes worn or
broken, simply replace the entire assembly. If the pump is taken out of service for a period of time
(such as during winter), flush the pump out with clean fresh water and drain thoroughly before stor-
ing. Ensure that the cord is protected from wear and abrasion.
NEVER ATTEMPT TO REPLACE OR SHORTEN THE CORD!
Service and
Maintenance:
1. RISK OF ELECTRIC SHOCK This pump is supplied with a grounding conductor and a ground-
ing-type attachment plug (3-prong plug). To reduce the risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle. Do not remove the grounding
pin.
2. RISK OF SEVERE ELECTRIC SHOCK Connect only to a grounded receptacle protected
by a ground-fault circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section
680-51 of the national electric code. Contact a qualified electrician if you cannot verify that the
receptacle is protected by the GFCI.
3. TO REDUCE THE RISK OF ELECTRICAL SHOCK:
A. Never use an extension cord to connect unit to electrical supply; provide a properly located
GFCI outlet.
B. Never bury the 3-prong plug of the cord, it is not waterproof and severe electric shock will
occur.
Your Beckett FR Series pump is cooled and lubricated with water. If the pump is plugged in while it
is out of the water, it is normal for it to rattle. However, while it will continue to operate if allowed to
run dry, it will sustain permanent heat damage after 30 minutes. Your Beckett FR Series pump is in-
tended to pump fresh water only. Do not use to pump oils, solvents, fuels, or salt water. Do not allow
to freeze.
SAFETY
WARNING:
Note:
PUMP MODEL #
VOLTS Hz AMPS WATTS
MAX.
HEAD
APPROXIMATE PUMP FLOW (GPH @ HEAD)
USING 1” ID HOSE
0’ 1’ 3’ 5’
FR250 115 60 .45 31 5’-11” 350 290 200 80
FR400 115 60 .68 32 6’-6” 500 418 268 115
FR600 115 60 .75 34 7’-8” 680 600 437 283
FR800 115 60 .90 70 12’-9” 900 814 652 512
PUMP MODEL NUMBER AND INFO LOCATED ON PUMP BACKPLATE NEAR POWER CORD
CAUTION:
1. This pump has been evaluated for use with water only.
2. Disconnect pump from power source before handling, servicing or working in the water in which the
pump is operating.
B E C K E T T
C O R P O R A T I O N
N o r f o l k V i r g i n i a
Question and Answer IconNeed help?

Do you have a question about the Beckett FR Series and is the answer not in the manual?

Beckett FR Series Specifications

General IconGeneral
TypeSubmersible
Housing MaterialPlastic
Impeller MaterialPlastic
Applicationfountains, ponds
Cord Length6 feet
Voltage120V
Inlet/Outlet Size0.5 inches
Weight1.5 lbs

Summary

Safety Warnings

Risk of Electric Shock

Use properly grounded receptacle, do not remove grounding pin.

Risk of Severe Electric Shock

Connect to GFCI-protected receptacle. Verify GFCI protection with an electrician.

Reducing Electrical Shock Risk

Avoid extension cords and burying the plug. Ensure GFCI outlet is properly located.

Operational Cautions

Water Use and Servicing

Pump evaluated for water only. Disconnect power before servicing or working in water.

Dry Running and Water Type

Pump is water-cooled; dry running causes damage. Use only fresh water, do not allow to freeze.

Assembly and Operation Instructions

Nozzle Adaptor Instructions

Details on installing and adjusting Spray Head, Waterbell, and Bubbler nozzles for various water effects.

Two-Way Valve Operation

Instructions on how to adjust the two-way valve for full flow, restricted flow, or shut-off.

Pump Installation

Guidance on placing the pump in the pond, connecting accessories, and initial operation checks.

Prefilter Cleaning

Procedure for cleaning the filter when pump flow is reduced to maintain performance.

Pond Accessories

Bio-Filter Types

Description of Inline Bio-Filters and Pre-Bio-Filters for pond filtration and health.

UV Clarifier

Inline UV Clarifier for clarifying green water and improving pond environment with UV light.

Water Features

Spitters

Easy-to-install secondary water features that return water as a tube, available in many varieties.

Water Course/Stream

Molded plastic features with rock texture for natural look, attach via vinyl hose, various sizes.

Small Waterfall

Molded plastic features returning water as a wall/stream, simple to install, may need rocks/shrubs.

Medium Waterfall

Molded plastic features, often installed with skimmer systems, require more installation knowledge.

Fountain Art

Cast resin figurines attaching to pump for accent features, larger than spitters, provide art.

Pond Accent Accessories

Pond Lights

Low voltage lights to add interest and depth to ponds and water features at night.

Plant Baskets

Molded plastic baskets for pond plants, allowing water and nutrients while containing roots.

Changing the Two-Way Valve

Valve Option

How to convert the two-way valve into a one-way valve for simplified use.

Valve Conversion

Step-by-step instructions for disassembling and reassembling the valve components.

Customer Limited Warranty

Pump and Accessories Warranty

Warrants pump and accessories against defects for 2 years, excluding rotor/impeller and filter.

Rotor/Impeller Warranty

Warrants rotor/impeller assembly against defects for 1 year from date of purchase.

Warranty Exclusions

Excludes consumer damage, abuse, altered cords, misuse, or failure to follow safety instructions.