Commissioning
Status info Beckhoff
P24Vxxxx UPS
Beckhoff 24V
UPS con-
nected to
CP903x ISA or
PCI card
APC Back-UPS
Pro 280
APC Smart-
UPS 420
Description
eBatteryStatus
BatteryU
nknownS
tatus if no
battery
found.
Only with
UPS
software
version
>=2.0.0.6
and UPS
firmware
>= 25.1.I
BatteryO
k
BatteryU
nknownS
tatus if no
battery
found.
BatteryO
k
X X The current
status of the
UPS batteries.
eCommStatus X X X X The status of
the
communication
path to the
UPS.
ePowerStatus X X X X Reports the
status of utility-
supplied power
into the UPS.
nPowerFailCnt X X *X *X Power fail
counter.
Increments
every time the
UPS service
detects power
fail.
CX2100-09x4 71Version: 1.3