6.4.3.9 Forced On
You need to go to the Treatment Forced On submenu to set the forced activation. The input for the
forced activation of the filter pump is defined here. The filter pump runs at normal speed as long as there is
a signal on the input.
The switch for the forced activation must be connected to terminal E11.
6.4.3.10 Forced Off
You need to go to the Treatment Forced Off submenu to set the forced deactivation. The input for the
forced deactivation of the filter pump is defined here. The filter pump is switched off as long as there is a
signal on the input.
The switch for the forced deactivation must be connected to terminal E12.
6.4.4 Warming Settings Menu
6.4.4.1 Heating
You need to go to the Warming Heating submenu to set the auxiliary heating. This is shown in Figure
9. The following parameters can be set:
- Sensor: defines whether a water sensor is available. The heating function can be called up only if a
sensor is available. If a water sensor is available, its temperature values are displayed on the start
screen.
- Heating: defines whether the heating function should be used to warm up the water temperature.
- Temperature: defines the target value of the swimming pool water
- Delay: defines the delay time after which the heating should be activated after dropping below the
target value (max. 20 min)
- Overrun: defines how long the filter pump should continue to run at normal speed after reaching the
target temperature, regardless of the switching times.
- Forced: defines whether the filter pump must be switched on for heating purposes outside of the
switching times.
- Hysteresis: defines the minimum required deviation between the target and actual temperature of
the swimming pool water to activate the heating.