Press “HOLD/REST to select test mode A. You need to watch the multimeter to adjust the KBCV voltage.
You can press “KYBD” or “STEP” to adjust the value until it close to target level “-5 V”(±1 mV).
(Press “STEP1” “STEP2” “STEP3” or “STEP4” to select the speed of adjust “X1”X2” “X3” or “X4”)
Press “RESET/ACCENT to select test mode B.
Press “KYBD” or “STEP to adjust the value until it close to target level “0 V (±1 mV).
Press ARP/SETEND to select test mode C.
Press “KYBD” or “STEP to adjust the value until it close to target level “5 V (±1 mV).
Press “REC to save and nish CV calibration.
Calibration done, power o the CRAVE.