EasyManua.ls Logo

Behringer EUROGRAND EG2080 - 8 Troubleshooting

Behringer EUROGRAND EG2080
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
EUROGRAND EG2080-RW/BK
8. TROUBLESHOOTING
Problem
Remedy
The instrument cannot be switched on
V
Check the connection between mains plug and wall outlet (see chapter 3.1).
No sound
V
Check the position of the MAIN VOLUME control (see chapter 3.2).
V
Check the SPEAKER button status (see chapter 5.4).
V
Check that the sound generator is switched on (see chapter 7.3.3).
The foot pedals do not work properly
V
Check that the pedal cable is properly connected to the PEDAL jack on th
e
underside of the EG2080 (see chapter 2).
The left foot pedal has no effect
V
Check in EDIT menu E4.1 that the soft pedal function is enabled (see chapte
r
6.5.8).
Audio signal is distored
V
Cut back the volume using the MAIN VOLUME control.
Sound is too low/high
V
Check whether the LED above the TRANSPOSE switch is lit. If so, transposition
is
active. Press the button to switch if off.
Effect is not audible
V
Perhaps no effect has been selected or its intensity is too low. Check that th
e
REVERB and EFFECT LEDs are lit and select an appropriate effect intensity (se
e
chapters 5.2.2 and 5.2.3).
Music sequencer/DEMO mode cannot be
selected
V
DEMO mode must not be active when you switch to music sequencer mode
.
Conversely, the music sequencer must be off before you can switch to DEMO mode.
The music recorded with the music
sequencer has been lost
V
When you re-record a track this will automatically erase the previously recorde
d
data on this track.
Music sequencer playback cannot be started
V
Playback can only be started when the memory of the music sequencer contain
s
data. Perhaps no data have been recorded.
V
Perhaps no tracks have been activated for recording. Proceed as described i
n
chapter 6.5.3.
The music sequencer has not stored the
entire recording
V
The music sequencer is limited in its capacity (approx. 10,000 notes). When th
e
memory is full, all further data will be lost. Play only as many notes as the sequence
r
can store before the display starts flashing, thus signaling that the memory is full.
The display shows
FUL
V
The memory of the music sequencer is full. If you do not want to erase/re-recor
d
your recording, be sure to save the recorded song via MIDI to a music computer (se
e
chapters 7.3.2 and 7.3.3) before you start a new recording.
The music piece recorded on the music
sequencer plays back too slow/fast
V
The playback tempo of the music sequencer follows the current tempo setting
.
Press the SELECT button until the TEMPO LED lights up, then simultaneously pres
s
the two

buttons to play back the recording at its original tempo.
The tuning of the instrument does not match
the tuning of other instruments
V
Check the settings in the EDIT menus
E1
and
E2.1
and adjust them if necessary
,
as described in chapter 6.6.3. Standard setting: 440 Hz, equal tuning.
Key velocity does not work properly
V
Check whether one of the LEDs above the VELOCITY button is lit. If necessar
y
activate the dynamic response of your choice by pressing the VELOCITY button (se
e
chapter 6.6.1).
V
Some sounds do not respond to key velocity (see chapter 10.2).
When the instrument is switched off all
settings are lost
V
When first switched on, the EG2080 always uses the default settings. To sav
e
your personal settings please set the memory function as described in chapter 6.6.5.
The EG2080 does not play back notes
received via MIDI IN
V
Set the receive channel, on which the EG2080 is to receive MIDI data, in the EDI
T
menu
E7.2
, as described in chapter 7.3.3.
The EG2080 does not transmit MIDI data via
MIDI OUT
V
Set the transmit channel, on which the EG2080 is to send MIDI data, in the EDI
T
menu
E7.1
, as described in chapter 7.3.3. Demo and music sequencer data are no
t
transmitted via MIDI.
The EG2080 does not respond to all MIDI
commands
V
The EG2080 supports only those commands listed in the MIDI Implementatio
n
Chart.
V
Be sure that the device sending MIDI data and the EG2080 do not have a MID
I
filter activated (see chapter 7.3.3).
The piano sounds strange
V
Check whether one of the LEDs above the EFFECT button is lit, i.e. whether
a
modulation effect is active. If so, press the button until all LEDs are off, i.e. no effec
t
is active.
V
Perhaps you have selected two sounds at the same time. Press one of the soun
d
buttons in the SOUND SELECT section to select a single sound.
The display shows
ERR
V
An internal error has occurred. Switch the instrument off, wait for about 3
0
seconds, then switch it back on. If the error message shows again, please contac
t
your BEHRINGER support desk. Further information can be found a
t:
www.behringer.com.
8. TROUBLESHOOTING