985-40000-01175 Rev.A
2021-02-16
Condential, for internal use only. Not to be reproduced.
page 3 of 5
Synthesizers and Samplers
MONOPOLY
VCO1 OFFSET and SCALE Calibration
Figure 1: Keys used in the Calibrations
Figure 2: Bottom Panel Trimmers
Calibration Procedure
Turn the front panel VCO1 LEVEL to 10.
Turn TRANSPOSE to DOWN, press and hold A2 key (Figure 1) and adjust the VCO1 OFFSET trimmer on the bottom panel
(Figure 2) while observing the guitar tuner display.
Follow all steps in the order in which they are presented.