EasyManua.ls Logo

Behringer MS-1-BK User Manual

Behringer MS-1-BK
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Synthesizers and Samplers
MS-1-BK /
MS-1-BU / MS-1-RD
Analog Synthesizer with 32 Full-Size Keys,
3340 VCO with 4 Simultaneous Waveforms,
VCF, NovaMod FM Sources, 32-Step Sequencer,
Arpeggiator and Live Performance Kit
985-40000-01104 Rev.A
2021-02-03
page 1 of 5
Condential, for internal use only. Not to be reproduced.
User Support Bulletin
Introduction
The unit is carefully calibrated at the factory. The performance may change over time or due to environmental changes,
and the following recalibration procedures can be used to bring it back to its factory settings.
Equipment required
1. A multimeter (with 1 mv resolution)
2. A 3.5 mm cable (mono or stereo should be ne)
Question and Answer IconNeed help?

Do you have a question about the Behringer MS-1-BK and is the answer not in the manual?

Behringer MS-1-BK Specifications

General IconGeneral
BrandBehringer
ModelMS-1-BK
CategorySynthesizer
LanguageEnglish

Summary

Introduction and Equipment

Equipment Required

List of necessary tools for calibration, including a multimeter and audio cable.

Preparation for Calibration

Initial Setup and Control Settings

Power on for 30 minutes, ensure stable temperature, remove cables, and set specific controls.

Calibration Procedure Overview

Overview of calibration types: Internal CV, Output CV, and External CV.

Internal CV Calibration

Initiating Internal Calibration

Press 'KYBD + STEP' during power-on, then 'Shift + STEP1' to begin.

Output CV Calibration

Output CV Calibration Modes and Functions

Defines button functions and test modes (A, B, C, D) for calibrating output voltage.

Performing Output CV Calibration Steps

Step-by-step guide to connecting the multimeter and adjusting output voltages for test modes.

External CV Calibration

Connecting and Initiating External Calibration

Connect CV out to CV in, then press 'Shift + STEP3' to start.