Synthesizers and Samplers
MS-1-BK /
MS-1-BU / MS-1-RD
page 4 of 5page 4 of 5
Connect the Multimeter to CV Out as shown below.
Carry out the Internal CV Calibration before starting this Output CV calibration.
Press “Shift + STEP2” to enter user Output CV calibration mode.
Press “HOLD/REST” to select test mode A. You will need to watch the multimeter to adjust the output voltage.
Press “KYBD” or “STEP” to adjust the CV value until it is close to target level “0V”.
(Press “STEP1” “STEP2” “STEP3” or “STEP4” to select the incremental adjustment size “X1” “X2” “X3” or “X4”)
Press “RESET/ACCENT” to select test mode B.
Press “KYBD” or “STEP” to adjust the CV value until it is close to target level “1V.
Press “ARP/SETEND” to select test mode C.
Press “KYBD” or “STEP” to adjust the CV value until it is close to target level “3V”.
Press “PATTERN/BANK” to select test mode D.
Press “KYBD” or “STEP” to adjust the CV value until it is close to target level “5V”.
Press “REC” to save and nish Output CV calibration.