Press “Shift + STEP1” to start Internal CV calibration.
All of the sequencer LEDs will light up in sequence after this has nished.
Press “KYBD + STEP” then power on device. All the sequencer LEDs will light up.
Wait for calibration to nish.
Internal CV Calibration
Output CV Calibration
In this mode, these buttons have new functions:
There are four test modes A / B / C / D to be calibrated. Their target voltage is 0V / 1V / 3V / 5V respectively.
Button Name Function
HOLD/REST Select test mode A
RESET/ACCENT Select test mode B
ARP/SETEND Select test mode C
PATTERN/BANK Select test mode D
SHIFT —
PAGE —
PLAY/STOP —
REC Save
Button Name Function
STEP1 Select X1 (about ±1 mV)
STEP2 Select X2 (about ±4.5 mV)
STEP4 Select X3 (about ±9 mV)
STEP4 Select X4 (about ±45 mV)
STEP5 —
STEP6 —
STEP7 —
STEP8 —
KYBD Decrease
STEP Increase