13
E
2.2.1 Editing parameters
Please refer to Table 2.1 for the structure of the parameters and the meanings of the abbreviations.
Display Function Parameter Range Default Value
GTH Gate Threshold -90 to -40 dB, OFF OFF
CTH Threshold -70 to 0 dB, OFF OFF
CRA Ratio 1:1 to 88:1, INF:0 1:1
CAT Attack Time 0 to 250 ms 0 ms
CRT Release Time 0.05 to 5 s 5 s
ULT Ultramizer Process 0 to 100 0
OUT Outgain Gain -24 to +24 dB 0 dB
LTH Limiter Threshold -36 to 0 dB, OFF 0 dB
Compressor
Tab. 2.1: Fader functions in PROCESS mode
The first five parameters in the <PROCESS> menu are contained in all six bands. The last three entries pertain
to the complete frequency range, however. Please see chapters 2.4.1 and 2.4.2 for the definitions of the
parameters.
+ Parameters edited in the <PROCESS> menu have a global effect on all six bands.
2.2.2 Program administration
A program stores all of the parameter settings affecting the signal. Global hardware settings such as the
configuration of the inputs and MIDI interface, i.e. the setup level 2 settings, are not stored in the respective
programs. The ULTRA-DYNE PRO has over 100 program memory locations that contain the factory presets,
as well as room for your own creations.
Fig. 2.2: <MEMORY> menu
Press the softkey B (Memory) in the <PROCESS> menu to access the <MEMORY> menu. The Up and Down
cursor keys can be used to select and listen to programs in this menu. An information window displaying the
selected program appears as soon as you press one of the cursor keys. At the same time, the displayed
preset is automatically played. Use softkey D (A/B) to compare it with the program you have been editing.
The currently active program is indicated by a bold letter in the pictogram: A is the edited version, while B is
the selected program. To load the program, press softkey A (LOAD) and follow the instructions in Chapter
2.2.3. Softkey C (CLEAR) clears your current program from the memory and permits the selection of a
default preset.
+ The message CLEAR WORKSPACE is displayed when the softkey C (CLEAR) is pressed.
Confirm the query with OK to reset all current parameters to their defaults. Be sure to save
the edited program first if desired.
2. OPERATION