44
Installation RSPS20/25
Release
09
12/2019
EMC interference
emission
Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Marine
applications
b
b. Merchant Navy – applies to devices with the certification codes VU, U9, UY, UX, UT
Railway
applications
(trackside)
c
c. EN 50121-4 – applies to devices with the certification codes VT, UT, T9, TY
Sub-station
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
Radiated emission
EN 55032 Class A Class A Class A Class A
GL Guidelines — EMC 1 — —
FCC 47 CFR Part 15 Class A Class A Class A Class A
EN 61000-6-4 Fulfilled Fulfilled Fulfilled Fulfilled
Conducted emission
EN 55032 AC and DC supply connections Class A Class A Class A Class A
GL Guidelines AC and DC supply connections — EMC 1 — —
FCC 47 CFR Part 15 AC and DC supply connections Class A Class A Class A Class A
EN 61000-6-4 AC and DC supply connections Fulfilled Fulfilled Fulfilled Fulfilled
EN 55032 Telecommunication connections Class A Class A Class A Class A
EN 61000-6-4 Telecommunication connections Fulfilled Fulfilled Fulfilled Fulfilled
EMC interference
immunity
Standard
applications
a
Marine
applications
b
Railway
applications
(trackside)
c
Sub-station
applications
d
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge ±4kV ±6kV ±6kV ±8kV
EN 61000-4-2
IEEE C37.90.3
Air discharge ±8kV ±8kV ±8kV ±15kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 3000 MHz 10 V/m 10 V/m 20 V/m 10 V/m
IEEE 1613 80 MHz ... 1000 MHz — — — 35 V/m