Cabinet Construction For Your Appliance
The sizes of the unit for installing the appliance under
a worktop or in
a column unit are shown in figure.
T
o
provide
adeq
uate ventilation, there mu
st be
approp
riate ventilation op
ening, the p
anel to whi
ch
the oven is fitted should have a gap of at least 70 mm
at the rear.
The unit panels next to the appliance must be heat
resista
nt. In the case of veneered wood units, glues
must be resistant to a temperature of 120°C.
Fitting Your Appliance
Fit the appliance into its surround (bene
ath a work-top
or above another appliance) by inserting screws into
the 2 holes that can be seen in the frame of the oven
when the door is open.
Note:
Your appliance must be mounted on a flat
surface for
the full width and depth of the product
Connect Power Supply Cord
Pull open terminal board cover at rear pa
nel of
appliance.
Fit wires through on terminal board and make
connections to terminals.
Engage wires into plastic clip. Secure plastic clip
with supplied screws.
Close the terminal board cover.
Mounting Screws
Plastic cli
Plastic clip
Securing
6
Hard Wired Appliances :
When making the mains supply conductor connections to the terminal
block within the terminal box , please ensure that minimum clearances
are being maintained between individual conductors and conductors/
connectors to the adjacent metal surfaces of the terminal box itself ,
where possible add heat shrink sleeves to any bare conductor end/
connectors prior to securing.