5 GAL(19L) AIR COMPRESSOR
1635-709
PROBLEM
The pressure
is low or
there is not
enough air.
The
compressor
overheats.
There is
moisture in
the discharge
air.
POSSIBLE CAUSE SOLUTIONS
There is a leak at one of the fittings.
Check the fittings with soapy water.
Tighten or reseal leaking fittings (apply
plumber’s tape on threads). Do not over
tighten.
The tank ball valve is open. Close the ball valve.
The air intake is restricted.
Prolonged excessive use of air.
Clean or replace the air filter element.
Decrease the amount of air used.
There is a hole in the air hose.
The tank leaks.
The valve is leaking.
Check the air hose and replace it if
necessary.
Replace the tank immediately. Do not
attempt to repair it. Replace the tank
Check for worn parts and replace them if
necessary. Check for worn parts and
replace them if necessary.
There is condensation in the air tank
caused by a high level of atmospheric
humidity or because the air compressor has
not been running long enough.
Drain the air tank after each use. Drain the
air tank more often in humid weather and
use an air-line filter.
The valve is leaking.
The ventilation is inadequate. Relocate the compressor to an area with
Cooling surfaces are dirty. Clean all cooling surfaces on the pump
Replace worn parts and reassemble using
new plumber's tape.