7
2) GENERAL INFORMATION
To ensure a good operation of these automatic devices, the gate to be automated should meet the following requirements:
- good strength and stiffness.
- hinges should have a minimum backlash and allow for smooth and regular manual operations.
- when closed, the gate leaves should correctly overlap for their entire height.
Warning: BILL30 is not equipped with electric limit switches or mechanical stoppers. It is mandatory that the gate leaf be equipped with mechanical
stoppers fitted to the ground (Fig.2 ref. A and B).
3) TECHNICAL DATA
BILL 30M BILL 30MA
Motor power supply 230Vac 50/60Hz 115 Vac 50/60Hz
Absorbed rating 240W 240W
Consumption
1,1 A 2,2 A
Max. thrust 2800 N 2800 N
Operating jogging 30 % 30 %
Protection level IP54
Operating temperature -20°C / +50°C
Capacitor 8 μF 31,5 μF
Useful stroke 300 mm
Noise <70 dB
Lubrication Permanent grease
Weight 5,7 kg 5,7 kg
4) OPERATING LIMITS
The following tables show the permitted maximum weight and width figures of the gate leaves.
Max gate leaf weight (kg)
100 300 350
Max gate leaf width (m)
2,5 2,1 1,8
In case of wind effect the limits can be significantly reduced.
5) HOW TO INSTALL THE SYSTEM
1) Define the height of the system from ground (the most centred possible with respect to the main door and corresponding to a rugged crossbeam).
2) Weld the P plate, taking account of figures X and Y of Fig. 2/3.
3) Release the actuator, as shown in the instruction manual. When the gate is closing, temporarily lock the S* bracket by keeping the K measure as per
Fig. 2/3. In these conditions, the actuator must not be positioned entirely at end of stroke, but 10mm extra-stroke should be still available.
By manually opening the gate leaf, check that the actuator does not hit the leaf or the pillar.
4) Only after this check, carry out the final welding of the S bracket. The actuator should be perfectly flat.
Important: the respect of dimensions indicated in Fig. 3 ensures the optimal operation of the automatic system. These different dimensions may cause
malfunctions.
In any case, the manufacturer shall be held unharmed with respect to damages caused by the non-respect of the dimensions indicated.
If it is not possible to carry out welding, adjustable brackets, which can be mounted by using screws (art B.SR), are available as optional accessory.
Fix the actuator to the bracket by means of screws and nuts supplied. Use washers as shown in Fig. 4.
Note: The difference between measures X and Y shall be never exceed 40mm. Greater differences cause the unsmooth movement of the gate.
Dimensions M and X should be carefully checked to avert that the actuator hits the pillar (dim. M) or the leaf (dim. Z).
The total stroke of the actuator is around 320mm. The stroke, however, cannot be entirely used. An extra stroke of around 10 mm should be always
provided both in the closing and opening phases.
* In the BILL 30 geared motor, the difference in height of brackets P and S shall be nil. These brackets should be therefore fitted at the same height (Fig.
1, ref. A}
6) WIRE CONNECTIONS
BILL 30 is supplied with a pre-cabled wire, around 80 cm long, to be connected to the junction box fitted to the pillar:
BLACK Gear 1
BROWN Gear 2
GREY Motor, common
Yellow/Green Earth
Note:
The motor cable shall be replaced only by an authorised assistance centre.
IT IS MANDATORY to connect the system to ground by using the special GND terminal, as provided by regulations in force.
WARNING
The insurance policy, which covers any damages or injuries caused by manufacture faults, requires that the installation comply with regulations in force
and Benincà original accessories be used.