When the board is switched on, the software version is displayed for around 5 sec
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
MENU FUNCTION
MIN-MAX-(Default)
MEMO
PARAMETERS
TCA
Automatic closing time. Active only with logic “TCA”=ON.
At the end of the set time the control unit orders a closing manoeuvre.
1-240-(40s)
TM1
Operating time, motor 1. The operating time is adjusted at normal speed dur-
ing motor 1 opening and closing phases. See Paragraph “Adjustment of the
gate leaf speed”.
By setting the value to 0, the operation is performed with around 2 seconds
of pick-up and then the movement is carried on at reduced speed for the
entire stroke.
0-180-(5s)
TM2
Operating time, motor 2. The operating time is adjusted at normal speed dur-
ing motor 2 opening and closing phases. See Paragraph “Adjustment of the
gate leaf speed”.
By setting the value to 0, the operation is performed with around 2 seconds
of pick-up and then the movement is carried on at reduced speed for the
entire stroke.
0-180-(5s)
TPED
The opening percentage of motor 1 (pedestrian function) is adjusted.
If the logics NOLS=ON, the opening percentage will always be 100%, in spite
of the preset value.
If TM1<5 sec., the opening percentage will always be 100%, in spite of the
preset value.
25-50-75-100
(50%)
TSLD
Duration of braking. Preset a value which must be higher than the braking.
See section “Adjustment of speed”
1-30-(15s)
PMo1
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at normal speed - Motor 1.
1-99-(50%)**
PMC1
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at normal speed - Motor 1.
1-99-(50%)**
PMo2
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at normal speed - Motor 2.
1-99-(50%)**
PMc2
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at normal speed - Motor 2.
1-99-(50%)**
TDMo
Mot.2 opening delay time.
Regulates the delay time of motor 2 on opening with respect to motor 1
0-15-(2s)
TDMC
Mot.1 closing delay time
Regulates the delay time of motor 1 on closing with respect to motor 2
0-40-(3s)
TLOc
Electric lock activation time. The value is expressed in 1/10s (0=0s - 50=5s). 0-50 (5=0,5s)
SLDs
Motor speed during braking is adjusted. Values are expressed in percentage
with respect to normal operating speed.
20-99 (50)
Pso1
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at reduced speed - Motor 1.
1-99-(50%)**
Psc1
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at reduced speed - Motor 1.
1-99-(50%)**
Pso2
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at reduced speed - Motor 2.
1-99-(50%)**
Psc2
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at reduced speed - Motor 2.
1-99-(50%)**
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
COMPLY WITH REGULATIONS IN FORCE!
** 1: maximum sensitivity - 99:minimum sensitivity.