13
MENU FUNCTION
ON-OFF-(Default)
MEMO
LOGIC
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or
transmitter impulse has no effect during the opening phase.
Off: condominium function disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase,
the activation of the photocell causes the automatic closure 3sec
after the total opening of the gate. It is activated only with TCA:ON
Off: rapid closing disabled.
(OFF)
Sld
Enables or disables slowing.
On: Slowing active.
Off: Slowing excluded.
If the logics NOLS=ON, braking cannot be excluded.
(ON)
PP
Selects the operating mode of the ”Step by step button” and of the
transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor
starts.
Off: Pre-blinking disabled.
(OFF)
Blco
The lock function in the opening phase is enabled or disabled.
On: Enabled lock function. Only with logics NOLS=OFF.
After activation of the opening limit switches, the control unit delays
stop by approximately 0.5sec, so as to allow a better stop of the gate
leaf against the stoppers.
Off: Disabled lock function.
(OFF)
Blcc
The lock function in the closing phase is enabled or disabled.
On: Enabled lock function. Only with logics NOLS=OFF.
After activation of the closing limit switches, the control unit delays
stop by approximately 0.5sec, so as to allow a better stop of the gate
leaf against the stoppers.
Off: Disabled lock function.
(ON)
CLOC
Selects the mode of the OPEN input
On: OPEN input with CLOCK function.
To be used for connection to a timer for timed opening/closing. (Con-
tact CLOSED- gate open, Contact open, normal operation).
Off: OPEN input with OPEN function
(OFF)
htr
Enables or disables Man present function.
On: Man Present operation.
During the entire operation, the OPEN/CLOSE push-buttons must
be kept pressed. When the STOP input opens, the motor stops. All
safety inputs are disabled.
Off: Automatic operation.
(OFF)
mloc
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vac/O,5A max.
Before each opening manoeuvre the power supply is interrupted for
the time set by the parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vac for the time
set by the parameter TLOC.
(OFF)
1mot
Select the 1/2 motors operating mode:
On: Only motor 1 operating.
Off: Both motors operating.
(OFF)