When the LEDs switch back again to the original configuration, the control unit has completed
the memory reset.
NOTE:
The transmitters are memorised on an EPROM memory (U2), which can be extracted from the
control unit and inserted in a new CORE control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the opening/closing of the
motor.
TRANSMITTER REMOTE LEARNING
If the transmitter code is already stored in the receiver, the remote radio learning can be carried
out (without accessing the control unit).
IMPORTANT: The procedure should be carried out with gate in the opening phase, during
the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in
memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel
to be matched to the new transmitter. The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected
at item 2. The flashing light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode
immediately.
LED DIAGNOSTICS
The red LED indicates the activation of inputs according to the legend hereunder:
STOP on with fixed light
PHOT rapid flashing
SWO 1 flash with 2-second interval
SWC 2 flashes with 2-second interval
OPEN+CLOSE 3 flashes with 2-second interval
By flashing slowly, the red LED also indicates that the unit is powered.
The green LED indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
APERTURA 1 flash with 1-second interval
CHIUSURA 2 flashes with 1-second interval
Open gate without TCA on with fixed light
Open gate with TCA rapid flash
Closed gate LED off