PMo2
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
ing phase, at normal speed - Motor 2.
1-99-(50%)**
PMc2
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at normal speed - Motor 2.
1-99-(50%)**
TDMo
Mot.2 opening delay time.
Regulates the delay time of motor 2 on opening with respect to motor 1
0-15-(2s)
TDMC
Mot.1 closing delay time
Regulates the delay time of motor 1 on closing with respect to motor 2
0-40-(3s)
SLD1
Adjusts motor 1 speed during slowing phases. Value expressed in percentage of
normal functioning speed.
30-70 (40%)
SLD2
Adjusts motor 2 speed during slowing phases. Value expressed in percentage of
normal functioning speed.
30-70 (40%)
Pso1
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
ing phase, at reduced speed - Motor 1.
1-99-(20%)**
Psc1
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 1.
1-99-(20%)**
Pso2
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
ing phase, at reduced speed - Motor 2.
1-99-(20%)**
Psc2
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 2.
1-99-(20%)**
SeaU
The intervention threshold of the anti-crashing device (Encoder) during the phase
at normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
SEAR
The intervention threshold of the anti-crashing device (Encoder) during braking
is adjusted *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
COMPLY WITH REGULATIONS IN FORCE!
With motors without limit switch and/or encoder it adjusts the sensitivity of the sensor which causes arrest during
slowing phase.
** 1: minimum force/torque - 99: maximum force/torque
LOGIC (LOG)
MENU FUNCTION
ON-OFF-(Default)
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter
impulse has no effect during the opening phase.
Off: condominium function disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the
activation of the photocell causes the automatic closure 3sec after the total
opening of the gate. It is activated only with TCA:ON
Off: rapid closing disabled.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
Blco
Enables or disables the block function in opening.
On: Block function enabled. To use only with motors equipped with Limit
switch. After the intervention of the opening Limit switch the control unit delays
arrest by about 0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled
(OFF)
Blc
Enables or disables the block function in closing.
On: Block function enabled. To use only with motors equipped with Limit
switch. After the intervention of the opening Limit switch the control unit delays
arrest by about 0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled.
(OFF)