Programming
Transmitters can be memorised and separate channel modes
can be set using the button “P” (see Fig.1/2). To go from one
programming mode to the next press the button P within
3 secs from one press and another. Once having selected
a programming mode, wait for about 3-4 secs and a LED
signal with indicate that programming has been entered (see
“Operations” column).
Table 1 lists the various programming modes.
* After pressing the button on the first transmitter the receiver
will wait 5 secs to memorise another transmitter.
In this way all the transmitters being associated with one channel
can be recorded in sequence. After the 5 secs the receivers exits
the programming mode. When using this method of recording in
sequence it is best to temporarily remove the antenna thereby
reducing the receiver’s range and limiting disturbance.
N.B.: Once a programming mode has been entered, other
modes cannot be accessed. When programming several
functions complete one programming sequence, indicated by
the LED going out, and restart with a new programming mode.
TABLE 2
Mode LED Function Operazioni
1
1
rapid blink
Set pulse mode
If the P button is not pressed within 5 secs the channel is reset to the
default pulse mode (1 sec switching).
Press the button P for at least 2 secs
2
2
rapid blinks
Select switching time
If the P button is not pressed within 5 secs the LED will start blinking at a
rate of 1 blink/sec until the button P is pressed.
The number of blinks counted before pressing the P button selects the
switching time, as shown in table 3.
Press the button P for at least 2 secs
3
3
rapid blinks
Set
Bistable mode
If the P button is not pressed within 5 secs the channel is set to the bista-
ble mode: the relay changes status on each pulse.
Press the button P for at least 2 secs
4 Off No function Normal status.