15
TABLE 3
LED
Blinks
Switching
Time
LED
Blinks
Switching
Time
LED
Blinks
Switching
Time
LED
Blinks
Switching
Time
1 1s 9 9s 17 3,5m 25 5m
2 2s 10 10s 18 4m 26 6m
3 3s 11 30s 19 4,5m 27 7m
4 4s 12 60s 20 5m 28 8m
5 5s 13 1,5m 21 1m 29 9m
6 6s 14 2m 22 2m 30 10m
7 7s 15 2,5m 23 3m
8 8s 16 3m 24 4m
Technical Characteristics ONE.2WB/WI/WO
Frequency
433,92 MHz
Power supply
21÷28 Vac
12÷28 Vdc
Range
Without antenna 30m
with antenna 100m
Channels
2
Relay contact
1A/24 Vdc
Working temperature
-20/+70°C
Consumption in standby
10 mA
Consum. ch. 1 or 2 actuated
42 mA
Consum.ch. 1 and 2 actuated
66 mA
Times Mode
This function is only necessary when one of the two channels
has to be set to be timed (from 1 sec to 10 min) or with bistable
operation. The pulse operating mode is set by default (1 sec
switching). To set the times enter mode 4 (for channel 1) or
mode 5 (for channel 2) and wait until the end of the 5 rapid
blinks. The Times submenu is described in table 2.
Resetting the memory
Cut off the power to the receiver. Press and keep pressed the
button P. Restore the power keeping the button P pressed. The
LED will light up red, after 5 secs it will blink rapidly alternating
green-red, release the button. Wait for the LED to go out. The
memory is now completely erased.