blcc
Enables or disables the block in closure function.
On: block function enabled.
Off: Block function disabled.
(OFF)
mloc
Selects the type of electric lock used.
On: Magnetic electric lock, normally powered according to the Vloc setting. Output en-
abled with gate closed.
Off: Latch electric lock, normally not powered.
Before each opening movement, it is supplied according to the Vloc setting for the time set
by the TLOC parameter.
(OFF)
cvar
Enables or disables the cloned ARC transmitters.
On: The AK series transmitters closed from an ARC transmitter already stored are enabled.
Off: The cloned transmitters are not enabled.
(ON)
rem
Enables or disables remote learning of the radio transmitters, as indicated in the
“Transmitters remote learning” paragraph.
On: Remote learning enabled.
Off: Remote learning disabled.
(ON)
esa
Enables or disables the “ESA” energy saving functionality.
On: The control unit, once the manoeuvre has terminated and enabling time is up of the
service light, removes the power supply to the accessories output, setting in stand-by
status.
The power supply of the accessories however remains enabled, only for the necessary time,
if the AUX1/AUX2 parameters need it.
Off: Energy saving disabled. To use if you want to have the accessories power supply
always enabled, for example if using 24 Vdc, or other devices that need to be always
powered.
(ON)
RADIO (RAD)
MENU FUNZIONE
PP
Selecting this function, the receiver sets in standby (Push) of a transmitter code to assign to the step-step function. Press
the transmitter key you intend to assign to this function.
If the code is valid, it is saved and the message OK is displayed
2Ch
Selecting this function, the receiver sets in standby (Push) of a transmitter code to assign to the second radio channel.
Press the transmitter key you intend to assign to this function.
If the code is valid, it is saved and the message OK is displayed
ped
Selecting this function, the receiver sets in standby (push) of a transmitter code to assign to the pedestrian opening
function (see TPED parameter). Press the transmitter key you intend to assign to this function.
If the code is valid, it is saved and the message OK is displayed
STOP
Selecting this function, the receiver sets in standby (Push) of a transmitter code to assign to the STOP function. Press
the transmitter key you intend to assign to this function.
If the code is valid, it is saved and the message OK is displayed
n tx
Selecting this function, the LCD display shows the number of transmitters currently saved in the receiver.
CLR
Selecting this function, the receiver sets in standby (Push) of a transmitter code to delete from the memory.
If the code is valid, it is cancelled and the message OK is displayed
RTR
Completely deletes the receiver memory. Confirmation is required of the operation.
By selecting this function, the receiver sets in standby (Push) of a new PGM press to confirm the operation.
At the end of the deletion, the message OK is displayed.
NUMBER OF MANOUEVRES (Nman)
It displays the number of complete cycles (open+close) carried out by automation. The first press of the <PG> button displays the first
4 digits, the second press displays the last 4. e.g. <PG> 0012 >>> <PG> 3456: executed 123.456 cycles.
MAINTENANCE CYCLES (maci)
This function allows you to enable the maintenance signal request after a number of manoeuvres established by the installation tech-
nician. To enable and select the number of manoeuvres, proceed as follows:
Press the <PG> button. The display shows OFF, which indicates the function is disabled (default value).
With the <+> and <-> buttons, select one of the numerical values proposed (from OFF to 100). The values should be intended as
hundreds of manoeuvre cycles (e.g.: the value 50 indicates 5000 manoeuvres). Press the OK button to enable the function. The dis-
play shows the message PROG. The maintenance request is signalled to the user while maintaining the flashing indicator light on for
another 10 s after conclusion of the opening or closure manoeuvre.