DSP 2500 Inverter System
10.15.07 17 028-0009-200
Three NEMA output receptacles protected by a 20A
push to reset circuit breaker
Two Three (TBD) IEC 320 output receptacles
protected by a 15A push to reset circuit breaker
One 120/240VAC Bulk Terminal Block Output (L1, N,
L2, G) protected by a single-pole 20A rocker style
breaker
Parallel Module Option: None
Alarm: Potential free contact (NO, C, NC), issued when
Output AC is no longer present
Phoenix “Spring Clamp” style connector
Indicators
Optical Display: Output voltage present
Mains synchronized
Parallel module synchronized
Fault
Overload
Agency Approvals
Listed to UL 1950
Radio interference degree: Class B (EN 55022)
Switching times: 100 ms