Bedienungsanleitung
Operating manual
Notice d‘emploi
Gebruiksaanwijzing
Instrucciones de servicio
Bruksanvisning
Istruzioni d’uso
BENNING MM 3
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Münsterstraße 135 - 137
D - 46397 Bocholt
++49 (0) 2871 - 93 - 0 Fax ++49 (0) 2871 - 93 - 429
www.benning.de eMail: duspol@benning.de
Bild 1: Gerätefrontseite
Fig. 1: Front tester panel
Fig. 1: Panneau avant de l‘appareil
Fig. 1: Voorzijde van het apparaat
Fig. 1: Parte frontal del equipo
Fig. 1: Framsida
ill. 1: Lato anteriore apparecchio
08/ 2004
BENNING MM 3
08/ 2004
BENNING MM 3
       
Bild 2: Gleichspannungsmessung
Fig. 2: Direct voltage measurement
Fig. 2: Mesure de tension continue
Fig. 2: Meten van gelijkspanning
Fig. 2: Medición de tension contínua
Fig. 2: Likspänningsmätning
ill. 2: Misura tensione continua
Bild 3: Wechselspannungsmessung
Fig. 3: Alternating voltage measurement
Fig. 3: Mesure de tension alternative
Fig. 3: Meten van wisselspanning
Fig. 3: Medición de tensión alterna
Fig. 3: Växelspänningsmätning
ill. 3: Misura tensione alternata
Bild 4: Gleichstrommessung
Fig. 4: DC current measurement
Fig. 4: Mesure de courant continu
Fig. 4: Meten van gelijkstroom
Fig. 4: Medición de corriente contínua
Fig. 4: Likströmsmätning
ill. 4: Misura corrente continua
Question and Answer IconNeed help?

Do you have a question about the Benning MM 3 and is the answer not in the manual?

Benning MM 3 Specifications

General IconGeneral
Diode testYes
Product typeDigital multimeter
Product colorBlack, Red
Frequency range0.001 - 200 kHz
AC current range0.0000001 - 20 A
DC voltage range0.001 - 600 V
Resistance range0.1 - 20000000 Ω
Capacitance range0.0001 - 200000 nF
Measuring categoryCAT III 300V
Placement supportedHandheld multimeter
Battery type9V
Power sourceBattery
Battery voltage9 V
Number of batteries supported1
Display digits4 digits
Weight and Dimensions IconWeight and Dimensions
Depth31 mm
Width84 mm
Height175 mm
Weight340 g

Summary

Operating Instructions

Safety Instructions

Contents of Delivery

Tester Description

General Specifications

General specifications for the BENNING MM 3

Provides general specifications for the BENNING MM 3 multimeter.

Environmental conditions

Electrical specifications

Direct voltage ranges

Details ranges, resolution, accuracy, and overload protection for DC voltage.

Alternating voltage ranges

Details ranges, resolution, accuracy, and overload protection for AC voltage.

Direct current ranges

Details ranges, resolution, accuracy, and overload protection for DC current.

Alternating current ranges

Details ranges, resolution, accuracy, and overload protection for AC current.

Resistance ranges

Details ranges, resolution, accuracy, and test current for resistance.

Diode and Continuity Testing

Specifies accuracy and conditions for diode and continuity tests.

Capacitance ranges

Details ranges, resolution, accuracy, and frequency for capacitance.

Frequency ranges

Details ranges, resolution, accuracy, and overload protection for frequency.

Measuring with BENNING MM 3

Measurement preparation

Covers essential steps before performing measurements.

Voltage and current measurement

Guides on how to measure voltage and current.

Resistance Measurement

Instructions for performing resistance measurements.

Diode Testing

Procedures and expected results for diode testing.

Continuity Testing with Buzzer

How to perform continuity tests and interpret buzzer feedback.

Capacitance Measurement

Steps and precautions for measuring capacitance.

Frequency measurement

Instructions on how to measure frequency.

Maintenance

Instrument safe-guarding

Guidelines for ensuring instrument safety and when to stop use.

Cleaning

Instructions on how to clean the multimeter.

Battery replacement

Step-by-step guide for replacing the battery.

Fuse replacement

Procedures for safely replacing fuses.

Calibration

Recommendation for recalibrating the instrument.