1A GENERAL WARNINGS
The instruction manual is an integral part of the product and it must
thereforebekeptcarefullyandmustaccompanytheappliance;if
themanualislostordamaged,anothercopymustberequested
from the Technical Assistance Service.
Boilerinstallationandanyotherassistanceandmaintenance
operationmustbecarriedoutbyqualiedpersonnelaccord-
ing to current local and national regulations.
For installation, it is advisable to contact specialised personnel.
Theboilermustonlybeusedfortheapplicationforeseenby
the manufacturer. The manufacturer shall not be liable for
anydamagetopersons,animalsorpropertyduetoerrorsin
installation, calibration, maintenance or due to improper use.
The safety and automatic adjustment devices must not be
modied,duringthesystemlifecycle,bythemanufactureror
supplier.
This appliance produces hot water, therefore it must be con-
nected to a heating system and/or a domestic hot water
mains, compatible with its performance and output.
Incaseofwaterleakage,closethewatersupplyandcontact
theTechnicalAssistanceServiceimmediately.
In case of absence for long periods time, close the gas sup-
plyandswitchofftheelectricalsupplymainswitch.Incaseof
riskoffrost,emptytheboiler.
From time to time check that the operating pressure of the
hydraulicsystemdoesnotdecreaseunder1bar.
In case of failure and/or malfunctioning, deactivate the appli-
ance,anddonottrytorepairorintervenedirectlyonit.
Appliance maintenance must be carried out at least once a
year: program it with theTechnicalAssistance Service will
avoidwastingtimeandmoney.
C.A.I. models: the ventilation openings are vital for correct
combustion.
Boileruserequirestostrictlyobservesomebasicsafetyrules:
Do not use the appliance in any manner other than its in-
tended purpose.
Itisdangeroustotouchtheappliancewithwetordampbody
parts and/or in bare feet.
Under no circumstances cover the intake grids, dissipation
grids and ventilation vents in the installation room with cloths,
paperoranyothermaterial.
Do not activate electrical switches, telephone or any other
object that causes sparks if there is a smell of gas. Ventilate
theroombyopeningdoorsandwindowsandclosethegas
central tap.
Donotplaceanythingintheboiler.
Donotperformanycleaningoperationiftheapplianceisnot
disconnectedfromthemainpowersupply.
Do not cover or reduce ventilation opening of the room where
the generator is installed.
Donotleavecontainersandinammableproductsinthein-
stallation room.
Do not attempt to repair the appliance in case of failure and/
or malfunctioning.
It is dangerous to pull or twist the electric cables.
Children or unskilled persons must not use the appliance.
Do not intervene on sealed elements.
C.A.I. models: do not cover or reduce the size of the ventila-
tion openings in the room where the boiler is installed. The
ventilation openings are vital for correct combustion.
For better use, remember that:
- aperiodicexternalcleaningwithsoapywaternotonlyimproves
its aesthetic aspect but also preserves panelling from corrosion,
extendingitslifecycle;
- if the wall-mounted boiler is enclosed in pendant furniture, leave
at least 5 cm for ventilation and maintenance;
- installation of an room thermostat will favour a greater comfort, a
morerationaluseoftheheatandenergysaving;theboilercan
also be connected to a programming clock in order to manage
ignitionandswitchingoffduringthedayorweek.
2A IGNITION
FirstignitionmustbecarriedoutbypersonnelfromtheTechnical
AssistanceService.Atthesametime,ifitisnecessarytoputthe
applianceinserviceagain,carefullyfollowthedescribedoperations.
Tostart-uptheboileritisnecessarytocarryoutthefollowingop-
erations:
- power the boiler
-openthegastappresentinthesystemtoallowfuelow
- turn the mode selector (3-g.1a)tothedesiredposition:
Summer mode:turningtheselectortothesymbolsummer
(g.2a)thetraditionalfunctionofonlydomestichotwaterisacti-
vated.Ifthereisadomestichotwaterrequestthedigitaldisplay
showsthehotwatersystemtemperature,theicontoindicatethe
hotwatersupplyandtheameicon
Winter mode: by turning the mode selector within the area
marked+and-(g.2b),theboilerprovidesdomestichotwater
and heating. If there is a heat request, the boiler switches on
and the digital monitor indicates the heating water temperature,
theicontoindicateheatingandtheameicon(g.3a).Ifthere
is a domestic hot water request, the boiler switches on and the
digitaldisplayshowsthehotwatersystemtemperature,theicon
toindicatethehotwatersupplyandtheameicon(g.4a)
Adjusttheroomthermostattotherequiredtemperature(~20°C)
Adjustment of domestic hot water temperature
Toadjustdomesticwatertemperature(bathrooms,showers,kitch-
en, etc.), turn the knob with symbol
(g. 2b) within the area
marked + and -.
Theboilerisstandbystatusuntil,afteraheatrequest,theburner
switchesonandthedigitaldisplayshowsthehotwatersystemtem-
perature,theicontoindicatethehotwatersupplyandtheameicon
The boiler will be in function until the adjusted temperature is
reached,afterwardsitwillbein“standby”again.
Environment Automatic Adjustment System Function
(S.A.R.A.) g. 6a
By setting the heating water temperature selector to the area
marked by AUTO - temperature value from 55 to 65°C - the
S.A.R.A. self-adjusting system is activated: the boiler varies the
deliverytemperature according totheclosingsignal of theroom
thermostat. When the temperature set with the heating water tem-
perature selector is reached, a 20 minutes count begins. If during
this period the room thermostat still requests heat, the value of the
settemperatureautomaticallyincreasesby5°C.
When the new value is reached, other 20 minutes count begins.
If during this period the room thermostat still requests heat, the
valueofthesettemperatureautomaticallyincreasesby5°C.
This new temperature value is the result of the temperature set
manuallywiththeheatingwatertemperatureselectorandthein-
crease of +10 °C of the S.A.R.A function.
After the second increasing cycle, the temperature value is re-
storedtothevaluesetbytheuserandtheabovementionedcycle
isrepeateduntiltheambientthermostatrequestisfullled.
3A SWITCHING OFF
Temporary switching off
In case of absence for short periods of time, set the mode selector
(3-g.1a)to
(OFF).
Inthisway(leavingtheelectricityandfuelsuppliesenabled),the
boilerisprotectedbythefollowingsystems:
- Anti-frost device: when the temperature of the water in the boil-
erfallsbelow5°C,thecirculatorand,ifnecessary,theburnerare
activated at minimum output levels to bring the water tempera-
turebacktothevaluesforsafety (35°C). During the anti-frost
cycle,thesymbol
appears on the digital monitor.
- Circulator anti-blocking function: an operation cycleis acti-
vatedevery24hours.