EasyManuals Logo

Beretta MYNUTE X R User Manual

Beretta MYNUTE X R
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
31
ENGLISH
NOTE
With reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product data sheet and the labelling for room heating appliances, for mixed
heating appliances, for all those appliances for enclosed space heating, for temperature control devices and solar devices:
ADDED DEVICES CLASS BONUS
OUTDOOR TEMPERATURE SENSOR II 2%
OT CONTROL PANEL V 3%
OUTDOOR TEMPERATURE SENSOR + OT CONTROL PANEL VI 4%
Serial number plate
Heating function
Qn Nominal heat delivery
Pn Nominal heat output
Qm Reduced heat delivery
IP Degree of Protection
Pms Maximum heating pressure
T Temperature
NOx NOx class
Parameter Symbol MYNUTE X 20 R MYNUTE X 30 R MYNUTE X 40 R Unit
Seasonal space heating energy efciency class - A A A -
Water heating energy efciency class - - - - -
Rated heat output Pnominal 19 29 29 kW
Seasonal space heating energy efciency ηs 93 93 93 %
Useful heat output
At rated heat output and high-temperature regime (*) P4 19,5 29,2 29,2 kW
At 30% of rated heat output and low-temperature regime (**) P1 6,5 9,7 9,7 kW
Useful efciency
At rated heat output and high-temperature regime (*) η4 87,6 87,8 87,8 %
At 30% of rated heat output and low-temperature regime (**) η1 97,7 97,5 97,5 %
Auxiliary electricity consumption
At full load elmax 28,0 28,0 28,0 W
At part load elmin 14,0 14,0 14,0 W
In Stand-by mode PSB 3,0 3,0 3,0 W
Other parameters
Stand-by heat loss Pstby 34,0 32,0 32,0 W
Pilot ame energy consumption Pign - - - W
Annual energy consumption QHE 36 53 53 GJ
Sound power level, indoors LWA 50 52 52 dB
Emissions of nitrogen oxides NOx 46 37 37 mg/kWh
For combination heaters
Declared load prole - - -
Water heating energy efciency ηwh - - - %
Daily electricity consumption Qelec - - - kWh
Daily fuel consumption Qfuel - - - kWh
Annual electricity consumption AEC - - - kWh
Annual fuel consumption AFC - - - GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
Qn (Hi) =
230 V ~ 50 Hz W
NOx:
Pms = bar T= °C
Pn =
Via Risorgimento 23/A - 23900 Lecco (LC) Italy
IP
50-30 °C
80-60
°C
Qn
Qn
Qm
kW
kW
kW
kW
kW
MYNUTE X R
80-60
°C