Install the connection cables.
Attention: coil - generator separated:
Feeler-, display- and potentiometer cables (control
cables) have to be installed separated from the
generator cables and if possible in a steel channel.
Don’t install coil cables in a steel channel and also laid
bundled.
Fasten the fuse and connection rail. Provide an easy
access and a splash-proof installation. In case of a fault
the fuses need an easy access to turn it on again.
It´s an additional backup of the system.
Grease filter with mounting frame for attachment to the
revision plate. The revisions plate has to be removable.
Install of the revisions plate (removable in case of
service) with the cut out of the air channel (installation
drawing) and connect with the adjustable air channel to
the plate and seal of the edges with alu tape to protect
it from greasy air.
The sucked air is only to provide over the air filters.
Clean the air filter weekly in the dishwasher. Don`t use
the induction unit without filter, because the electronic
components will be damaged.
Assemble a switch face plate with air outlets
Important: the air outlets should only open below to
avoid liquid. To clean this unit don`t use splash water!