Do you have a question about the BERTHOLD TECHNOLOGIES LB4710-050 and is the answer not in the manual?
Describes the purpose and application of the LB 471 Mini Switch as a level monitoring device.
Identifies the intended audience for the user's guide and personnel qualifications.
Explains the use of buttons, display, and LEDs on the evaluation unit's front panel.
Outlines the safety design principles and international radiation exposure limits.
Explains safety symbols used in the guide for hazard identification.
Compares the features and differences between standard and professional operating modes.
Explains individual parameters, their codes, values, and functions in detail.
Details the application of the LB 471 Mini Switch for level detection in various conditions.
Describes the system's safety function based on count rate changes and safe status modes.
Guides on the initial power-up sequence and display indications of the device.
Details the empty calibration process necessary to prepare the measurement.
Explains the non-contact Gamma absorption measurement principle of the LB 471 Mini Switch.
Describes the Geiger-Müller detector, its types, and protection.
Explains the zero count rate, its importance, and methods for its determination.
Details the empty calibration process and factors influencing it.
Provides instructions and safety precautions for transporting system components.
Guides on mounting the detector, including alignment and environmental considerations.
Lists common problems, their causes, and remedies for troubleshooting the device.
Explains the procedure for resetting the device to its factory settings.
Details procedures for checking the shielding and source locking mechanism.
Covers fundamental radiation protection principles, limits, and personnel responsibilities.
Explains how to calculate expected radiation exposure for safety precautions.
Lists technical specifications for the evaluation unit, including design, power, and temperature.
Provides technical data for GM, NaI, and Super-Sens detectors.
Presents the ATEX certificate for the evaluation unit.
Shows the ATEX certificate for the NaI detector.
Provides the ATEX certificate for the GM detector.
Shows technical drawings and specifications for NaI detectors with and without collimators.
Provides technical drawings and specifications for GM detectors, including Ex and non-Ex versions.
Presents technical drawings and specifications for Super-Sens detectors with various configurations.
Includes drawings and specifications for LB 744X point source shielding models.
Shows dimensional drawings for the evaluation unit in 19" rack, wall housing, and cassette formats.
Illustrates connection diagrams for 19" rack, wall housing, and cassette configurations.
| Brand | BERTHOLD TECHNOLOGIES |
|---|---|
| Model | LB4710-050 |
| Category | Switch |
| Language | English |