EasyManua.ls Logo

Beverage-Air BM23HC-B-28 - Electrical Connections and Operation; Initial Unit Start-Up; Cabinet Temperature Adjustment

Beverage-Air BM23HC-B-28
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual for BM Refrigerators Beverage-Air
Rev. 08/20Beverage-Air8
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the
machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to unsafe
cabinet temperature when GFI device trips from moisture.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out, and cool
air will ow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment.
A standard refrigerated unit has been set to maintain a
38°F cabinet temperature. Models with -Wine have a
control that can maintain a cabinet temperature between
40°F-60°F and are factory set at 47°F.
Before making temperature adjustments, allow the unit
to stabilize for 1 hour and verify that a temperature
adjustment is needed. If an adjustment is needed; turn
knob one number and allow the unit to stabilize for 1 hour
before rechecking the cabinet temperature. If additional
adjustment is needed, repeat process to achieve the
desired operation temperature.
Clockwise = Colder
Counter Clockwise = Warmer
Excessive tampering with temperature control could lead
to service diculties.
* For operation above 3000-ft altitude, have thermostat
adjusted by a qualied technical service representative.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be ammable.
ELECTRICAL
Turn the dial
clockwise to lower
the temperature or
counter clockwise to
raise the temperature.
To Adjust Cabinet Temperature

Related product manuals