EasyManua.ls Logo

Beyerdynamic MCS 20 - Page 21

Beyerdynamic MCS 20
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MCS 20 – MCS 223 Microphone Unit
53
english
No. Description Value
range
Factory
setting
14 “FiFo” = “Requ” + “Free”:
0 = MCS 223 does not turn off another microphone unit
1 = MCS 223 turns off another microphone unit
0 or 1 1
15 “FiFo” = “Requ” + “Free”:
0 = MCS 223 is not turned off by another microphone unit
1 = MCS 223 is turned off by another microphone unit
0 or 1 1
16 Warning signal in the “Free” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec. 45
17 After the speech time has elapsed in the “Free” mode
0 = Timer indicates the exceeded speech time (counts up)
1 = MCS 221 is turned off
0 or 1 0
18 Warning signal in the “Request” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec. 45
19 After the speech time has elapsed in the “Request” mode:
0 = Timer indicates the exceeded speech time (counts up)
1 = Timer stops (activated MCS 221 is turned off and the registered MCS 221
must be activated by the chairman with the “Requ” button)
2 = Timer starts again (activated MCS 221 is turned off and registered
MCS 221 is turned on)
0 ... 2 2
20 Speech time is displayed in minutes (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 99 min. 2
21 Speech time is displayed in seconds (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 59 sec. 30