ISTRUZIONI X PROGRAMMAZIONE CENTRALINA CLASSICA EVA CON DISPLAY
INSTRUCTIONS FOR PROGRAMMING CLASSICA EVA CONTROL UNIT WITH
DISPLAY
INSTRUCTIONS POUR LA PROGRAMMATION DE L'UNITÉ ÉLECTRONIQUE
CLASSICA EVA AVEC AFFICHEUR
PROGRAMMIERUNGSANLEITUNG STEUEREINHEIT CLASSICA EVA
CLASSICA EVACLASSICA EVA
CLASSICA EVA MIT DISPLAY
INSTRUCCIONES PARA LA PROGRAMACIÓN DE LA CENTRALITA CLASSICA
EVA CON DISPLAY
TECNICO
TECHNICIAN
TECHNICIEN
TECHNIKER
TÉCNICO
VU001_1010_Rev000_ISTRUZ_DOSAT_3D5_MAESTRO_CLASSICAEVA_TEC
Area Elettronica
ATTENZIONE: LE OPERAZIONI CONTENUTE IN
QUESTO MANUALE SONO CONSENTITE SOLO A
PERSONALE TECNICO QUALIFICATO.
WARNING: THE OPERATIONS INTO THIS
MANUAL ARE ALLOWED ONLY TO TECHNICAL
QUALIFIED.
ATTENTION: LES OPÈRATIONS CONTENU DANS
LE MANUEL SONT CONSENTIES SEULERENT À
TECHNICIENS QUALIFIÈS.
VORSICHT: DIE VERHALTENEN OPERATIONEN
IN DIESES HANDBUCH ERLAUBTEN NUR ZU
TECHNISCHEN QUALIFIZIERT.
PRECAUCIÒN: LAS OPERACIONES
CONTENIDAS EN ESTE MANUAL SON PERMITE
SÓLO A PERSONAL TÉCNICO CUALIFICADO.
ON 12:00
Question and Answer IconNeed help?

Do you have a question about the BFC CLASSICA EVA and is the answer not in the manual?

BFC CLASSICA EVA Specifications

General IconGeneral
BrandBFC
ModelCLASSICA EVA
CategoryCoffee Maker
LanguageEnglish

Summary

Programming Classica EVA Control Unit

Qualified Personnel Requirement

Manual operations are restricted to qualified technical personnel only.

Display Contrast and Brightness Adjustment

Contrast Adjustment Procedure

Procedure for adjusting the display contrast using a screwdriver.

Technician Level Programming

Entering Technician Configuration Mode

Initiate technician mode by pressing buttons 5 (P) and 3 simultaneously.

Language Selection

Select desired language by pressing button P for 10 seconds, then using buttons 1 and 2.

Name Configuration

Configure name by selecting letters using buttons 1 and 2, confirm with button 3.

Service Phone Number Configuration

Set service phone number by selecting digits with buttons 1 and 2, confirm with button 3.

Coffee Dispensing Duration (Function Crono)

Configure coffee dispensing duration in seconds, enable or disable the function.

Boiler Temperature Display Function

Enable/disable display of boiler temperature, requires temperature sensor.

Temperature Unit (°C/°F) Selection

Select temperature display unit (°C or °F) for boiler or steam pipe.

FillingUp + Coffee Association

Associate boiler water load with coffee dispensing, enable/disable function.

Dose Setting Configuration

Configure dose settings, enable or disable the function.

3 Coffees Key Functionality

Enable or disable the 3 coffees key function.

Tea Dispensing Pump Activation

Enable/disable pump activation for tea dispensing.

Steam Boiler Control Panel Assignment

Select control panel for steam unit, associate with desired buttons.

Display Steam Wand Temperature

View steam wand temperature, enable/disable display, requires steam control panel selection.

Pre-brewing Function and Time Setting

Configure pre-brewing time for each coffee dose, enable/disable function.

Water Level Probe Sensitivity

Adjust water level probe sensitivity (Low, Medium, High).

Maintenance Service Cycles Counter

Set service cycle counter for maintenance alerts without machine lockout.

Water Tank Filling Time-out

Set maximum time for filling water tank to desired level.

Water Filter Replacement Indicator Setup

Set water filter replacement indicator based on water volume.