FINAL CHECKS AND MAINTENANCE
Before the automated system is nally put into operation, and during maintenance work, perform the following checks
meticulously:
- Ax a door/gate identication plate, also ax a warning sign on the frame�
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more
specically, that nothing can be banged, crushed, caught or cut between the part being operated and the surrounding
parts�
- Make sure the motor automation settings are correct and that the safety and release systems are working properly�
- Make sure all components are fastened securely;
- In case of manual control, check starting and stopping operations;
- Make sure all safety devices are in good working order (photocells, sensitive edges, etc�) and that safety devices are
correctly adjusted�
- Impact forces can be reduced by using deformable edges�
- Make sure that the emergency operation works, where this feature is provided�
- Check opening and closing operations with the control devices applied�
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands
are undamaged�
- While performing maintenance, clean the photocells' optics�
- When the automated system is out of service for any length of time, activate the emergency release so that the
operated part is made idle, thus allowing the gate to be opened and closed manually�
- The maintenance described above must be repeated at least once yearly or at shorter intervals where site or installation
conditions make this necessary�
GATE MOVEMENTS
Gate status
Radio START
button
or
START input
Radio
PEDESTRIAN
button
OPEN input
Opening limit
switch trigger
Closing limit
switch trigger
STOP input Photocell trigger
Amperostop
trigger
(*)
Semi-automatic logic (TCA = O) - 4 steps
Closed Opens totally
If the gate is
closed (closing
limit switch) it
partially opens,
otherwise it fully
opens
Opens totally No eect No eect
Inhibits
movement
Inhibits opening
No eect
During
opening
Stops opening Stops opening No eect Stops opening No eect
Inhibits
movement
Stops opening to
clearance
Stops and
movement
is reversed
for 1s
Open Closes Closes No eect No eect No eect
Inhibits
movement
Inhibits closing No eect
During
closing
Stops closing Stops closing
Stops closing
and reverses
movement
No eect Stops closing
Inhibits
movement
Stops closing and
reverses movement
after clearance
Stops and
movement
is reversed
for 1s
Automatic logic (TCA = On) - 4 steps
Closed Opens totally
If the gate is
closed (closing
limit switch) it
partially opens,
otherwise it fully
opens
Opens totally No eect No eect
Inhibits
movement
Inhibits opening
No eect
During
opening
Stops opening
and closes after
TCA
Stops opening
and closes after
TCA
No eect
Stops opening
and closes after
TCA
No eect
Inhibits
movement
Stops opening to
clearance
Stops and
movement
is reversed
for 1s
Open Closes Closes No eect No eect No eect
Inhibits
movement
Inhibits opening No eect
During
closing
Stops closing Stops closing
Stops closing
and reverses
movement
No eect Stops closing
Inhibits
movement
Stops closing and
reverses movement
after clearance
Stops and
movement
is reversed
for 1s
(*) If the motor nds a xed obstacle, it runs the clearance manoeuvre�
56 - FABER BT - FABER L BT KIT