EasyManua.ls Logo

BFT SP 3500 - Page 27

BFT SP 3500
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Logic Denition
Default
Cross
out
setting
used
Optional extras
EXPO1
Conguration of
EXPO2 output
on input-output
expansion board
4-5
11
1 Output congured as SCA (gate open light).
2 Output congured as Courtesy Light command.
3 Output congured as Zone Light command.
4 Output congured as Stair Light.
5 Output congured as Alarm.
EXPO2
Conguration of
EXPO2 output
on input-output
expansion board
6-7
11
6 Output congured as Flashing light.
7 Output congured as Latch.
8 Output congured as Magnetic lock.
9 Output congured as Maintenance.
10 Output congured as Flashing Light and Maintenance.
11
Output congured as Trac Light control with TLB board.
TRAFFIC LIGHT
PREFLASHING
Trac light
pre-ashing
0
0 Pre-ashing switched o.
1 Red lights ash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red light 0
0 Red lights o when gate closed.
1 Red lights on when gate closed.
D812213 00100_08
SP 3500 - SP 3500 SF - 27
ENGLISH
INSTALLATION MANUAL