Logic Denition
Default
Cross
out
setting
used
Optional extras
EXPO1
Conguration of
EXPO2 output
on input-output
expansion board
4-5
11
1 Output congured as SCA (gate open light).
2 Output congured as Courtesy Light command.
3 Output congured as Zone Light command.
4 Output congured as Stair Light.
5 Output congured as Alarm.
EXPO2
Conguration of
EXPO2 output
on input-output
expansion board
6-7
11
6 Output congured as Flashing light.
7 Output congured as Latch.
8 Output congured as Magnetic lock.
9 Output congured as Maintenance.
10 Output congured as Flashing Light and Maintenance.
11
Output congured as Trac Light control with TLB board.
TRAFFIC LIGHT
PREFLASHING
Trac light
pre-ashing
0
0 Pre-ashing switched o.
1 Red lights ash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red light 0
0 Red lights o when gate closed.
1 Red lights on when gate closed.
D812213 00100_08
SP 3500 - SP 3500 SF - 27
ENGLISH