D812140 00200_01
ENGLISH
Terminal Denition Description
Aux
20
AUX 0 - 24V POWERED CONTACT (N.O.)
(MAX. 1A)
AUX 0 congurable output - Default setting FLASHING LIGHT.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN
ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTENANCE. Refer to “AUX
output conguration” table.
21
AUX output conguration
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required.
Aux logic= 10 - FLASHING LIGHT AND MAINTENANCE output.
Contact stays closed while leaves are operating. If the value set for the Maintenance parameter is reached, once the gate has nished moving and the leaf is closed, the contact closes for 10 sec. and opens for 5 sec.
4 times to report that maintenance is required.
Parameter min. max. Default
Personal
Denition Description
Maintenance
0 250 0
Programming number of
operations for maintenan-
ce threshold [in hundreds]
Allows you to set a number of operations after which the need for maintenance will be
reported on the AUX output congured as Maintenance or Flashing Light and Maintenance .
TABLE “B” LOGIC MENU - logic
Logic Denition
Default
Cross out
setting
used
Optional extras
AUX 0
Conguration of
AUX 0 output.
20-21
6
0
Output congured as 2nd Radio Channel.
1
Output congured as SCA (gate open light).
2
Output congured as Courtesy Light command.
3
Output congured as Zone Light command.
4
Output congured as Stair Light
5
Output congured as Alarm
6
Output congured as Flashing light
7
Output congured as Latch
8
Output congured as Magnetic lock
9
Output congured as Maintenance
10
Output congured as Flashing Light and Maintenance.
Protection
level
Setting the
protection level
0
0
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in
standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by repeating
the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
1
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
2
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
3
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
4
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference, if any.
EXPO1
EXPO2
Conguration of
EXPO1/2 output
on input-output
expansion board
6-7
11
9
Output congured as Trac Light control with TLB board.
10
Output congured as Flashing Light and Maintenance.
11
Output congured as Trac Light control with TLB board.
ON ON
OFF OFF
S1
S2
S3
+
-
OK
ON ON
OFF OFF
S1
S2
S3
+
-
OK
70 71
COM
STOP
S1
S2
S3
+
-
OK
S1
S2
S3
+
-
OK
8888
rst8
8888
. ...
J
1 2 3 4 5 6
!
<3s
+
13) RESTORING FACTORY SETTINGS (Fig.L)
WARNING: this operation will restore the control unit’s factory settings and all transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to people and animals.
- Cut o power to the board (Fig.L ref.1)
- Open the Stop input and press the - and OK keys together (Fig.L ref.2)
- Switch on the board’s power (Fig.L ref.3)
- The display will read RST; conrm within 3 sec. by pressing the OK key (Fig.L ref.4)
- Wait for the procedure to nish (Fig.L ref.5)
- Procedure nished (Fig.L ref.6)
ACCESS MENUS Fig. 1
x 2
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
***
ALT
0---
10--
150- 1520 ok
follow the user guide