ENGLISH
INSTALLATION MANUAL
Logic Denition
Default
Cross out
setting
used
Optional extras
SERIAL ODE
Serial mode
(Identies how board
is congured in a BFT
network connection).
0
0 Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1 Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
ADDRESS
Address 0 [ ___ ]
Identies board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
PUSH go
Push&Go
(Only for
E5 BT A12)
0
0 Logic not active
1 Manually pushing the stopped leaf toward the opening direction determines the automatic opening.
EXPI1
Conguration of
EXPI1 input on
input-output expan-
sion board.
1-2
1
0 Input congured as Start E command.
1 Input congured as Start I command.
2 Input congured as Open command.
3 Input congured as Close command.
4 Input congured as Ped command.
5 Input congured as Timer command.
6 Input congured as Timer Pedestrian command.
7 Input congured as Phot (photocell) safety.
8 Input congured as Phot op safety (photocell active during opening only).
9 Input congured as Phot cl safety (photocell active during closing only).
10 Input congured as Bar safety (safety edge).
11
Input congured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
12
Input congured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
13
Input congured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
14
Input congured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
output expansion board is switched automatically to safety device test input, EXPFAULT1
15
Input congured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/
output expansion board is switched automatically to safety device test input, EXPFAULT1
16
Input congured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
17
Input congured as safety Bar OP test, safety edge with inversion active only while opening, if while closing
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
18
Input congured as safety Bar CL test, safety edge with inversion active only while closing, if while opening
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
EXPI2
Conguration of
EXPI2 input
on input-output
expansion board.
1-3
0
0 Input congured as Start E command.
1 Input congured as Start I command.
2 Input congured as Open command.
3 Input congured as Close command.
4 Input congured as Ped command.
5 Input congured as Timer command.
6 Input congured as Timer Pedestrian command.
7 Input congured as Phot (photocell) safety.
8 Input congured as Phot op safety (photocell active during opening only).
9 Input congured as Phot cl safety (photocell active during closing only).
10 Input congured as Bar safety (safety edge).
11
Input congured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
12
Input congured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
EXPO1
Conguration of
EXPO1 output
on input-output
expansion board
4-5
11
0 Output congured as 2
nd
Radio Channel.
1 Output congured as SCA (gate open light).
2 Output congured as Courtesy Light command.
3 Output congured as Zone Light command.
4 Output congured as Stair Light.
EXPO2
Conguration of
EXPO2 output
on input-output
expansion board
6-7
11
5 Output congured as Alarm.
6 Output congured as Flashing light.
7 Output congured as Latch.
8 Output congured as Magnetic lock.
9 Output congured as Trac Light control with TLB board.
10 Output congured as Flashing Light and Maintenance.
11 Output congured as Trac Light control with TLB board.
TRAFFIC LIGHT
PREFLASHING
Trac light pre-
ashing
0
0 Pre-ashing switched o.
1 Red lights ash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LA P
ALWAYS ON
Steadily lit red light 0
0 Red lights o when gate closed.
1 Red lights on when gate closed.
THALIA - 37
D814123 0AA00_01