6. REGULAR MAINTENANCE
At the end of each use, empty and clean the inox body.
Wait for the boiler to be cool and the pressure gauge to show “0”, place a container under the
boiler and open with cauon the drain valve placed under the boiler leng the water out.
Open the draining tap use the handle/lever places on the front side of machine.
In order to protect gaskets, o-rings, it is important to spray grease on the handle couplings, on
the steam/water plug on the gun and on the steam/water socket on the machine.
To carry out an extraordinary cleaning, it is possible to pour into the boiler a glass of vinegar
and water. Then shake the steam generator and empty the boiler and rinse with only water. Do
not use any anscale product.
1
ATTENTION: BEFORE DRAINING THE WATER FROM THE BOILER, UNPLUG THE MACHINE
AND UNSCREW BY HALF A TURN THE SACURITY TAP TO RELEASE THE REMAINING PRESSU-
RE AND HEATH FROM THE BOILER.
THIS OPERATION MUST BE DONE DEPENDING ON THE USE OF THE MACHINE, AT LEAST
ONCE A MONTH. IF NOT, THE GUARANTEE WILL DECAY.