EasyManua.ls Logo

Bifold Orange EX200 - Table of Contents

Bifold Orange EX200
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EX200 Electro-Hydraulic Actuator Positioner
Bifold Orange Limited.
Drwg. No.: ORM0001 Issue : 1 Date : 24/06/2015 Page : 2 of 20
Contents
EX200 - ELECTRO-HYDRAULIC ACTUATOR POSITIONERS ............................................................................................................... 1
Features .......................................................................................................................................................................................................................... 3
EX200 Part Number Selection Chart .............................................................................................................................................................................. 4
Operation......................................................................................................................................................................................................................... 4
Physical ........................................................................................................................................................................................................................... 4
Wiring .............................................................................................................................................................................................................................. 4
EX200 Positioner set-up ................................................................................................................................................................................................. 5
Setting solenoid operating sense .............................................................................................................................................................................. 6
Setting retransmitted actual position signal drive type Sourcing or Sinking ...................................................................................................... 6
Setting the auxiliary solenoid and fault output sense .............................................................................................................................................. 6
Setting the command signal break default operation .............................................................................................................................................. 6
Setting the auxiliary solenoid and fault output interlock ......................................................................................................................................... 7
Setting the self-contained pump control options ..................................................................................................................................................... 7
Setting the stepping option timers ............................................................................................................................................................................ 7
Setting the HART private command enable and remote slow/fast operation ......................................................................................................... 8
First time operation ........................................................................................................................................................................................................ 9
Calibration ....................................................................................................................................................................................................................... 9
Normal operation - fault detection ................................................................................................................................................................................. 9
Self contained operation .............................................................................................................................................................................................. 10
Maintenance .................................................................................................................................................................................................................. 10
EX200/H Hart Version - HART Revision 7 + 16 bit Manufacturers and Device ID...................................................................................................... 11
HART Command Summary ...................................................................................................................................................................................... 11
Universal Commands ............................................................................................................................................................................................... 11
Common Practice Commands ................................................................................................................................................................................. 11
Private Commands ................................................................................................................................................................................................... 11
Specification ................................................................................................................................................................................................................. 13
EX200 Terminal Descriptions ....................................................................................................................................................................................... 14
EX200 in Din Rail Mount Enclosure Typical System Wiring diagram for a Safe Area Installation ........................................................................... 15
EX200 in Din Rail Mount Enclosure Dimensions and Front Panel ............................................................................................................................. 16
EXD2010 Ex d Enclosure System Typical Layout ....................................................................................................................................................... 17
EXD2010 Ex d Enclosure System Typical Wiring Drawing......................................................................................................................................... 18
EX200 in EXD2010 Ex d Enclosure PCB Assembly .................................................................................................................................................... 19
EXD2010 Enclosure Assembly ..................................................................................................................................................................................... 20
Manufacturer and Approvals Details ....................................................................................................................................................................... 20
Instructions for Safety ............................................................................................................................................................................................. 20