SYSTEM AIR PURGE PROCEDURE
1. Turn release valve counterclockwise one full turn
to the open position.
3. Rapidly pump the handle 6-8 times. Leave handle
in down position to expose oil ll plug.
2. Remove cover plate.
4. With a at blade screwdriver, push the oil ll plug
slightly to the side to purge trapped air from
system. (Use caution not to tear or puncture the
oil plug.)
6. Turn release valve clockwise to the closed
position.
5. Replace cover plate and the jack is now ready for
use. Check for proper pump action.
Screwdriver
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic
system as a result of product shipment and handling. This step is to be completed without any weight on the
jack.
7. Jack is now ready for use. Check for proper pump
action. (Repeat steps if neccessary).