IV. Setup BigRep
3. Press „Teach“ on the lasersensor AWLS
4. Drive printer 9.9/9.8mm up in Z from current position (--> G91 [relative mode]
enter & G1 Z9.8 F5000)
5. If „error41“ is displayed, go 0.1mm down
6. Press „Teach“ ==> „GooD“ should be displayed
change back to absolute mode with G90 + Enter
7. Request position with M114
8. Get the shown Z value for the config line:
leveling-strategy.three-point-leveling probe osett --> values
are displayed like this: X, Y, Z (for example: 150, 75, 16.2)
Leveling/Calibration: Extruder
Make sure that both extruders are at the highest position (turn adjusting screw
clockwise) and heated to 220°, bed to 60°.
1. Choose T0
2. Take feeler gauge 0.5mm and drive to absolute Z-position 0.5mm G1 X100
Y100 Z0.5 F700
3. Choose T1 and drive to the position G1 X100 Y100 Z0.5 F700
4. Calibrate second extruder
5. Start Firstlayer_adhession test (Starting high = 0.2mm), use vernier caliper!
6. If Extruder is to close the Z-probe Value needs to be decreased
7. If the Extruder is to far away the Z-probe Value needs to be increased
IV-I 2/2