I. Mechanics BigRep
I-C End stops
* 2016-04-07
Overview
End stops are the datum of each axes and make sure that the printer knows where
it is.
In general you need at least 3 end stops, 1 for each axis to define the homing
position.
BigRep end stops (see figure next page)
BigRep ONE comes with 6 optical end stops, two for each axis. The three addi-
tional end stops make sure that the printer always knows the maximum position
of each axis, even when the operator used the wrong build volume during slicing.
X- and Y-end stops are both fixed and not allowed to change.
The height of the Z
min
end stop has to be adjusted during the setup to define the
correct ratio between end stop and height of the printbed.
To adjust the correct height for Z
min
end stop please have a look at V-H Lev-
eling