925-0290 Rev A 3
PROCAP I
GENERAL SPECIFICATIONS
Supply: 24 TO 240 VAC or VDC
Load: 4VA
Ambient Temperature: (Electronics) -20° F to +145° F (-28° C to +62° C)
Sensitivity: 1 picofarad
Enclosure: PROCAP I Type 4X, 5, 9, & 12 (HAZ LOC CL II E, F, & G)
PROCAP I X Type 4X, 5, 7, 9, & 12 (HAZ LOC CL I C&D; CL II E,F, & G)
Fuse F1: 0.4A 250V Time Delay 5 X 20MM BinMaster P/N 328-0064
Relay Contact Rating: DPDT contacts; 10 Amps 250 VAC maximum
Fail-Safe: Switch selectable "High" or "Low" level modes.
Calibration: Set when probe is uncovered:
COARSE adjust; single turn potentiometer
FINE adjust; single turn potentiometer
Status Indicator: Internal LED indicates material in contact with probe.
PROCAP I has an external LED also
Time Delay: Independently adjustable up to 30 seconds
Probe Shield: Automatically compensates for material buildup on the
probe
Mounting: 1 1/4” or 3/4" NPT - When used in liquid applications the
stainless steel threads must be used to insure a proper
seal.
Conduit Entries: 3/4" NPT