63
11.3. ASH PAN DOOR AND COMBUSTION CHAMBER DOOR SEALS
The seals ensure the boiler air tightness and, thus, a proper performance.
It is necessary to check them regularly; if they are worn-out or damaged they should be replaced immediately.
You can find ceramic cord and self-adhesive fibre at the same Bronpi distributor where you bought your boiler.
These operations should be done exclusively by an authorised technician.
11.4. CLEANING THE CHIMNEY
When the pellet is burnt slowly, it produces tar deposits and other organic vapours that combined with the
humidity to create soot (creosote). An excessive accumulation of soot may cause problems in the smoke outlet
and the flue may catch fire if not maintained..
The cleaning of the boiler chimney should only be made when the equipment is cold. A chimney sweep should
perform this task and, at the same time, examine the smoke duct (it is recommended to write down the dates
of every cleaning and keep a register of them).
11.5. CLEANING THE GLASS
IMPORTANT:
Clean the glass only when it is cold in order to avoid possible explosion. You can use specific products. You
can find Bronpi vitro ceramic-cleaning product in the same Bronpi distributor where you bought your stove (see
drawing D83).
BREAKAGE OF GLASSES. The glasses, as they are vitro ceramic, resist until 750ºC and they are not subject to thermal
shocks. The breakage can only be caused by mechanical shocks (crashes or violent closing of the door, etc). Therefore, its
replacement is not included in the warranty.
11.6. EXTERNAL CLEANING
Do not clean the external surface of the boiler with water or abrasive products because they may damage the stove. Use a feather duster or
a moist rag
11.7. CLEANING THE ASH RESERVOIRS
In order to keep the validity of the guarantee period, it is mandatory that the cleaning of the
records is carried out by a technician authorized by Bronpi Calefacción, who will leave a
written record of the intervention made.
It is about cleaning the ash records of the boiler as well as the area of passage of the fumes.
First of all, it is necessary to thoroughly clean the interior of the combustion chamber, descaling the soot
adhered to the walls, as this makes difficult the heat exchange and rub with a steel brush the surfaces with
accumulated dirt.
It is also necessary to clean the chamber of the heat exchangers, as the soot that accumulates in them
makes difficult the correct circulation of the smoke. In order to access to these zones in the model
Hydrobox, you can do it directly from the front, opening the external door of the boiler. On the Hydrotex and
Hydroconfort models, to access to these registers, you must remove the original chamber from the boiler
where the display is located. In all cases, perform the following operations:
- Remove the record covers by loosening the different screws.
- Clean the ash deposited in the records.
- Mount back the covers.
- Check the tightness of the records.
EN