BirdDirectionalPowerSensors
12
5014 Specifications
SensorType Thrulinetwoelementlinesection
Elements
APMor43serieselements.Selecttwo
elementsfromthesameserie s,withRFLpower
1/10ofFWDpower.
FrequencyRange
1
23600MHz
Average Power Measurement
APMElements,ForwardorReflectedDirection
PowerMeasurementRange
1
0.1Wto1kW
Accuracy
2
±5%ofreading(95%c.l.)
Peak/AverageRatio,Max 10dB
43Elements,ForwardorReflectedDirection
PowerMeasurementRange 0.1Wto10kW
PowerMeasurementAccuracy
±5%offullscaleaveragepower
(95%c.l.)
Peak Power Measurement
43Elementsonly,Forwarddirectiononly
PulseWidth,Min
225MHz
25100MHz
>100MHz
15µs
1.5µs
800ns
Rep.Rate,Min 15pps
DutyCycle,Min
1x10
–4
Accuracy
2
±8%offullscalepeakenvelopepower(95%
c.l.)
Match Measurement
MatchRange
ReturnLoss
Rho()
VSWR
0to20dB
0.1to1
1.22to99.99
Uncertainty
TwicetheAvgPowerUncertainty
(Calculatedfromforwardandreflected
uncertainty)
SettlingTime,Max 2.5seconds
Impedance,Nominal 50ohms
InsertionLoss,Max 0.05dBupto1GHz
InputVSWR,Max. 1.05:1upto1GHz

Related product manuals