KQ-206-2
Quick Guide ECOLITE Regler
Deutsch .................................................................................................................................................... 2
Quick Guide ECOLITE Controller
English...................................................................................................................................................... 7
LHL3E/2EES-2Y
LHL3E/2DES-2Y
LHL3E/2CES-3Y
LHL5E/4FES-3Y
LHL5E/4EES-4Y
LHL5E/4DES-5Y
LHL5E/4CES-6Y
BITZER Kühlmaschinenbau GmbH
Peter-Schaufler-Platz 1 // 71065 Sindelfingen // Germany
Tel +49 7031 932-0 // Fax +49 7031 932-147
bitzer@bitzer.de // www.bitzer.de
Änderungen vorbehalten // Änderungen vorbehalten // Subject to changeSAP-Nr // 11.2019
PDF Download // 11.2019
Änderungen vorbehalten
Subject to change
Question and Answer IconNeed help?

Do you have a question about the Bitzer ECOLITE Series and is the answer not in the manual?

Bitzer ECOLITE Series Specifications

General IconGeneral
BrandBitzer
ModelECOLITE Series
CategoryController
LanguageEnglish

Summary

Quick Guide ECOLITE Controller Operation

Function Keys and Display Overview

Details the 4 function keys (F1-F4) and the controller's color display for operation and diagnostics.

Password Entry Procedure

Step-by-step guide to access controller settings by entering a specific password sequence.

Controller Parameter Configuration

Parameter Categories and Settings

Outlines parameter categories like CNF (Unit Settings), CPR (Compressor/CRII), FAN, and COR.

Refrigerant and Unit System Setup

Configuration of refrigerants (e.g., R404A, R134a) and unit system (SI or Imperial).

Compressor and CRII Configuration

Settings for compressor type and CRII configuration (e.g., number of cylinders).

Operation Mode and Room Control

Configuration for operation modes (e.g., LowSound, Eco) and room temperature control settings.

Controller Initialization and Operation

Start Release Procedure

Steps to initialize and start the controller's release sequence.

Clock Setting Procedure

Instructions for setting the controller's date and time accurately.

Displaying Operating Conditions

How to view current operating status, such as suction pressure or temperature.

Alarm and History Management

Checking Active Alarms

Procedure to check for currently active alarms on the controller.

Reviewing Alarm History

Steps to access and review the history of saved alarms, including code and timestamp.

Related product manuals