3-34 ScrPowerDown
Turn off the SCR. This function is only available on SPP-R210 SCR.
long ScrPowerDown(char *pResponse);
[Parameters]
* char *pResponse
[in, out] Response to power up
[Return Values]
Constant
Value
Description
SUCCESS
0
The function is successful.
WRITE_ERROR
-105
Data transmission failed.
BAD_ARGUMENT
-117
The specified argument is not correct.
NOT_SUPPORT
-124
The function is not supported.
SCR_RESPONSE_ERROR
-126
The response data is incorrect.
* Example
int ret;
char response = 0xff;
ConnectToPrinter(………..);
……
ret = ScrPowerDown(&response);
if (0x00 != response)
return;
……