DLE EOT n
[Name]
[Format]
[Range]
[Description]
Real-time status transmission.
ASCII DLE EOT n
Hex 10 04 n
Decimal 16 4 n
1 ≤n ≤4
Transmits the selected printer status specified by n in real-time, according
to the following parameters :
n = 1 : Transmit printer status.
n = 2 : Transmit off-line status.
n = 3 : Transmit error status.
n = 4 : Transmit paper roll sensor status.
n = 1 : Printer status
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off.
1 On 02 2 Not used. Fixed to On.
Off 00 0 Drawer open/close signal is LOW (connector pin 3).2
On 04 4 Drawer open/close signal is HIGH (connector pin 3).
Off 00 0 On-Line 3
On 08 8 Off-Line
4 On 10 16 Not used. Fixed to On.
Off 00 0 Not waiting for on-line recovery. 5
On 20 32 Waiting for on-line recovery.
6 - - - Undefined.
7 Off 00 0 Not used. Fixed to Off.
n = 2 : Off-line status
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off.
1 On 02 2 Not used. Fixed to On.
2 - - - Undefined.
Off 00 0 Paper is not being fed by using the PAPER FEED
button.
3
On 08 8 Paper is being fed by the PAPER FEED button.
4 On 10 16 Not used. Fixed to On.
Off 00 0 No paper-end stop. 5
On 20 32 Printing stops due to paper end.
Off 00 00 No error. 6
On 40 64 Error occurs.
7 Off 00 0 Not used. Fixed to Off.